VN-UG-01 issued 15/07/2019
Mo-2 HD DVR/ Monitor
User Guide
Warnings and Cautions
It is the user’s responsibility to read and to understand these
instructions prior to use of Peak Medical laryngoscopes.
Tracheal intubation requires specialized training. Only personnel who
have received training should be authorized to use video
laryngoscopes.
Dont attempt to use any laryngoscope unless pre-use checks, as
described in IFU of VNScope, have been carried out successfully.
Store in dry clean condition away from heat and light.
Charge monitor battery if it not in use at least once a week
Don’t charge battery during intubation
Dont use liquid or aerosol cleaners and disinfectors other that
specified by manufacturer
Don’t spill liquids of any kind onto product.
Never push objects of any kind into this product through opening
Don’t attempt to service this product yourself. Opening or removing
cover will void warranty.
Don’t insert or pull out memory TF card when the monitor is ON
In the vicinity of patients and in the treatment area use the monitor
only closed into the protective enclosure
Troubleshooting
If no image on the screen: turn off the monitor, plug off the camera, pull out the
memory card, connect the power adapter, and turn on again.
If still no image: turn off the monitor and continue to charge for additional 2-3 hours,
plug off the adapter and turn the monitor on. If the image appears, continue the charging.
Buttons and Connections
On-Screen Icons
Basic operations
1. Charging the battery
Internal Li-Ion battery could be charged via Mini USB port with supplied 5V
adapter and USB cable or via 5-12V port with a special adapter (is not
supplied).
2.Power ON
Plug-in connector of VNScope into monitor into AV-IN;
Press ON-OFF switch and wait for 10-15 secs till image appears on the
screen. Check the battery charge level;
. 3.Power OFF
Press ON-OFF switch for 3secs to switch off the monitor
4.Operation modes
Intubation mode(Record): perform intubation with connected VNScope
To record film* press button once to open an information screen and
press it again to start recording. To stop recording press to open
information screen and press once more to stop recording.
Intubation mode(Photo): perform intubation with connected VNScope
To take picture* press It takes 3 secs to finish processing.
Play back mode
*Recording will be performed only if TF memory card is inserted.
5.Play back Video/Photo
Select play back mode , press or to select Photo or Video
,according to file format, JPG or AVI .
To start play back video press to stop press again
6.Delete Video/Photo
Select play back mode , select the picture, press ,select “Delete”,
press , select “Current” press to delete.
To display thumbnail of films and pictures press and to choose
Thumbnail mode press again and chose the file, press . to delete
7.Zoom of image*
In intubation mode use to increase magnification
*In normal conditions no need to increase magnification as it decreases
quality of image.
8. System settings
Keep Loop Recording –“OFF to prevent scratch of previous records
and Screen Off –“OFF to avoid sudden switch off of the screen
Monitor warranty
This product’s warranty, provided by our company, covers a
period of 1 year from the date of purchase. All faulty parts and/or
functions, resulting despite the user’s normal use, will be repaired
and/or replaced at no charge during the warranty period.
However, if any of the malfunctions are caused by user
carelessness, inadequate maintenance, or natural disaster, we will
provide repair and/or replacement services for a fee regardless of
the warranty period. In the event, our product does not prove
suitable for your application you can return the product for an
exchange or refund. To claim, the product must be returned in
good condition within 14 days. Before returning a product, please
contact and provide us a serial number. The customer is
responsible for all shipping costs.
VNScope
Photo Video Loop TF Card Not in use Full Half Low Empty Charging
------------------Battery --------------------
Question and Answer IconNeed help?

Do you have a question about the PeakMedical Mo-2 and is the answer not in the manual?

Summary

Product Safety and Warnings

General Safety Precautions

Key instructions for safe use, storage, and maintenance of the device.

Specific Usage Cautions

Warnings against liquid contact, unauthorized servicing, and improper TF card handling.

Troubleshooting

No Image Resolution

Steps to resolve the issue where no image is displayed on the screen.

Image Recovery and Charging

Procedure for recovering image display and continuing charging.

Basic Operations

Battery Charging

Instructions for charging the internal Li-Ion battery via Mini USB or DC port.

Power ON;OFF

Steps to power the monitor on and off, including connection to VNScope.

Operation Modes

Performing intubation and capturing video or still images.

Playback and File Management

Navigating playback mode, viewing, and deleting media files.

Image Zoom and System Settings

Adjusting image magnification and configuring system settings.

Intubation Technique and Reference

4-Step Intubation Procedure

Detailed 4-step guide for performing intubation with the video laryngoscope.

VNScope Color Coding

Explanation of the color coding system used for VNScope.

Overview

This document describes the PeakMedical Mo-2 HD DVR/Monitor, a device designed for use with video laryngoscopes, specifically the Peak VN laryngoscope. It functions as a monitor and digital video recorder (DVR) to assist with intubation procedures.

Function Description

The Mo-2 HD DVR/Monitor serves as a visual aid during intubation by displaying real-time images from a connected video laryngoscope. It also has the capability to record both video and still images of the procedure. The device is equipped with an internal Li-Ion battery, which can be charged via a Mini USB port using a supplied 5V adapter and USB cable, or via a 5-12V port with a special adapter.

Usage Features

Powering On and Off: To power on, plug the VNScope connector into the monitor's AV-IN port, then press the ON-OFF switch and wait 10-15 seconds for the image to appear. The battery charge level should be checked upon startup. To power off, press the ON-OFF switch for 3 seconds.

Operation Modes: The monitor supports two primary operation modes:

  1. Intubation Mode (Record): This mode is used for performing intubation with a connected VNScope. To record video, press the record button once to open an information screen, and press it again to start recording. To stop recording, press the record button once more.
  2. Intubation Mode (Photo): This mode is for taking still pictures during intubation. To capture a picture, press the photo button. The device takes 3 seconds to process the image. Recording and photo capture are only possible if a TF memory card is inserted.

Playback Mode: Users can play back recorded videos and photos. To access playback, select the playback mode and use the navigation buttons to choose between Photo or Video, depending on the file format (JPG or AVI). To start video playback, press the play button; to stop, press it again.

Deleting Files: In playback mode, users can select a picture or video, then press the menu button, select "Delete," and confirm by pressing the menu button again to delete the current file. To view thumbnails of films and pictures, press the menu button and choose "Thumbnail" mode, then press it again to select a file for deletion.

Zoom Functionality: In intubation mode, the device allows for image magnification using the zoom buttons. However, it is noted that increasing magnification in normal conditions may decrease image quality.

System Settings: The monitor includes system settings such as "Loop Recording" and "Screen Off." It is recommended to keep "Loop Recording" set to "OFF" to prevent overwriting previous records. Similarly, "Screen Off" should be set to "OFF" to avoid the monitor suddenly switching off.

Intubation Technique with Video Laryngoscope: The manual outlines a 4-Step Technique for intubation using the Peak VN laryngoscope:

  1. Look in the Mouth: Introduce the video laryngoscope into the mouth using conventional direct laryngoscopy technique.
  2. Look at the Screen: Identify the epiglottis and manipulate the blade to obtain the best glottis view.
  3. Look in the Mouth: Guide the distal tip of the tube into position near the tip of the laryngoscope.
  4. Look in the Screen: Complete the intubation, rotating or angling the tube as needed for redirection.

Maintenance Features

Battery Care: The monitor's battery should be charged at least once a week if not in use. It is crucial not to charge the battery during intubation.

Cleaning and Disinfection: Only use liquid or aerosol cleaners and disinfectants specified by the manufacturer. Do not spill liquids of any kind onto the product.

General Care: Store the device in a dry, clean condition, away from heat and light. Do not insert or pull out the TF memory card when the monitor is ON. Do not push objects of any kind into the product through openings. Do not attempt to service the product yourself; opening or removing the cover will void the warranty. When used in the vicinity of patients or in the treatment area, the monitor should only be used when enclosed in its protective enclosure.

Troubleshooting: If no image appears on the screen, the user should turn off the monitor, unplug the camera, remove the memory card, connect the power adapter, and then turn it on again. If the image still does not appear, continue charging for an additional 2-3 hours, then unplug the adapter and turn the monitor on. If the image appears, continue charging.

Warranty: The product comes with a 1-year warranty from the date of purchase, covering faulty parts and functions under normal use. Malfunctions caused by user carelessness, inadequate maintenance, or natural disaster are not covered, and repair/replacement services for these will incur a fee. If the product is unsuitable for its application, it can be returned for exchange or refund within 14 days, provided it is in good condition. A serial number is required for returns, and the customer is responsible for all shipping costs.

PeakMedical Mo-2 Specifications

General IconGeneral
Oxygen Concentration93% ± 3%
ModelMo-2
ManufacturerPeakMedical
Input Power60Hz
Weight33 lbs (15 kg)