Instruction Manual
PCI 18/8
Condensing Combination
Space heating / Water
hea
t
er
61,419 BTU/h INPUT
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may result, causing property
damage, personal injury or death.
-Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
-WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance
•Do not touch any electrical switch; do not use any phone in your building
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department
-Installation and service be performed by a qualified installer, service agency or the gas supplier.
-Use of a properly calibrated electronic combustion analyzer MUST be used to install and/or service this appliance.
Approved in accordance with:
ANSI Z21.10 / CSA 4.3 - 2011

Questions and Answers

  • J
    Julia JimenezAug 14, 2025
    How to fix no flame on PENSOTTI Water Heater?
    • S
      Sarah GuerreroAug 14, 2025
      If your PENSOTTI Water Heater has no flame, first, check the mains gas supply. If the gas supply is ok, then the ignition electrode might be broken or grounded, and it should be replaced. Also, the gas valve might be malfunctioning, requiring a replacement. Check if the mechanical minimum adjustment or slow ignition adjustment on the gas valve is set too low and regulate them. For LPG water heaters, verify that the gas valve inlet pressure isn't too high and check the maximum pressure setting. Ensure that the power supply live and neutral wires are connected correctly. Finally, the ionization electrode might be malfunctioning or the ionization electrode cable might be disconnected; in both cases, the part should be replaced or the wire connected.
  • K
    Kelly MccarthyAug 18, 2025
    What to do if safety thermostat tripped on PENSOTTI PCI 18 Water Heater?
    • P
      phopkinsAug 18, 2025
      If the safety thermostat (203°F) or air pressure switch has tripped in your PENSOTTI Water Heater, it could be due to several reasons. The thermostat itself might be malfunctioning or out of calibration, requiring replacement. Check the wiring to ensure the thermostat cable is properly connected, as well as the air pressure switch. The switch itself could be out of order and need replacement. Also, inspect the inlet and outlet flue gas ducts for any obstructions. Finally, make sure the switch cable is stable and properly connected.
  • D
    davisangelaAug 21, 2025
    Why is there a flame detection malfunction on my PENSOTTI PCI 18 Water Heater?
    • K
      Kendra AdamsAug 21, 2025
      If you are experiencing a flame detection malfunction in your PENSOTTI Water Heater, the ionization electrode might be malfunctioning. Try cleaning it or replacing it. If the issue persists, the ionization electrode cable or the printed circuit board might be malfunctioning and need replacement.
  • Q
    qbeckAug 25, 2025
    How to fix fan printed circuit board on PENSOTTI PCI 18 Water Heater?
    • B
      Brandon SpencerAug 25, 2025
      If the PENSOTTI Water Heater's fan printed circuit board is malfunctioning, momentarily disconnect power to the appliance, then reconnect it. If the error code clears and the appliance operates normally, do not replace the fan circuit board. Otherwise, replace the part.
  • A
    Angelica HinesAug 28, 2025
    What causes heating sensor problem in PENSOTTI PCI 18 Water Heater?
    • A
      adam50Aug 28, 2025
      If your PENSOTTI Water Heater is showing a heating sensor issue, the sensor might be malfunctioning or out of calibration (resistance value 10 kOhms at 77 °F). In this case, replace the sensor. Also, check the electrical connection, as the sensor cable might be disconnected or wet.
  • G
    Geoffrey JacksonAug 31, 2025
    What does D.H.W sensor mean on PENSOTTI PCI 18 Water Heater?
    • N
      Nicole SteinAug 31, 2025
      If your PENSOTTI Water Heater displays a D.H.W sensor issue, it might be due to the sensor malfunctioning or being incorrect (resistance value 10 kOhms at 77 °F), requiring replacement. Alternatively, the sensor cable could be disconnected or wet, so check the electrical connection.
  • C
    Christine RoySep 3, 2025
    How to fix FLUESAFETY THERMOFUSE on PENSOTTI PCI 18?
    • F
      Frank GibsonSep 4, 2025
      If the FLUESAFETY THERMOFUSE is triggered in your PENSOTTI Water Heater, it could be due to a broken thermofuse, so replace the part. Also, check the electrical connection as the thermofuse cable might be disconnected. If the thermofuse is in lock-out mode due to high flue temperature, restart the system and check the thermofuse.
  • K
    Kimberly GoodmanSep 6, 2025
    Why is there no water in my PENSOTTI Water Heater?
    • S
      seanhamptonSep 7, 2025
      If there is no water in the PENSOTTI Water Heater system, it could be due to insufficient water pressure in the system (stops at 4.5 PSI (0.3 BAR)), so fill the system. Also, check the wiring, as the water pressure switch cable might be disconnected. The water pressure switch itself might be malfunctioning, requiring a replacement.
  • W
    Wanda JohnsonSep 10, 2025
    What does parameter programming request mean for PENSOTTI Water Heater?
    • H
      hamiltontaylorSep 12, 2025
      A parameter programming request on your PENSOTTI Water Heater indicates a loss of microprocessor memory or a new PCB, which requires you to reprogram the parameters.

Summary

Safety Warnings and Precautions

General Information

Installation Safety Warnings

Critical safety instructions for installing the water heater.

Installation Guide

Water Heater Installation

Step-by-step guide for mounting and securing the appliance.

Water Connections

Instructions for connecting domestic hot water and central heating pipes.

Gas Connection

Instructions for gas piping, pressures, and leak testing.

Electrical Connections

Requirements for electrical hookup, grounding, and surge protection.

Venting System

Critical guidelines for proper venting to prevent CO and ensure safety.

Appliance Commissioning

Commissioning Warnings

Essential safety and operational checks before initial startup.

Startup and Operation Check

Steps to safely start the water heater and verify its operation.

Appliance Regulation

Maintenance Procedures

Maintenance Safety Warnings

Crucial safety precautions before performing any maintenance.

Troubleshooting and Diagnostics

Guide to identifying and resolving common problems and error codes.

PENSOTTI PCI 18 Specifications