CALIBRATION
1. Set the tension scale on 60 lbs and the collar on 0. Place a string attached
to a tension calibrator in string gripper. Tension calibrator will indicate
the pounds of tension on tension head under actual stringing conditions.
Pull string until the locking lever releases. If it releases before 60 lbs or after
60 lbs., the following adjustment is needed. CAUTIION: Be sure to
release string holding tension calibrator. You are now ready for adjustment.
Electronic
Calibrator:
Manual
Calibrator: