Details FCC compliance for Class B digital devices and provides measures to correct radio interference.
Configure the receiver's local address code using dipswitches 5 and 6 for Channel 1.
Turn off PG2000 power and colorwheel switches, then remove the PG2000 body.
Straighten receiver antenna and place module on the left side of the unit, aligning with ribs.
Connect the 4-pin connector from the RF2000 to the PG2000, ensuring proper cable routing.
Drape the antenna forward into the fiber conduit area, keeping it straight along the outer perimeter.
Ensure the receiver module and antenna fit within the PG2000 housing and replace the body.
Install the 9V battery in the transmitter unit.
Use the transmitter's top buttons to select the desired channel (default is Channel 1).
Press the 'power on' button; a beep confirms signal transmission for up to 5 seconds.
Press the 'color on' button to activate the colorwheel with a 1/2 second signal delay.
Press the 'color off' button to freeze the current color; power cycling also turns it off.
Note that metal halide lamps may take 3-4 minutes to restrike after power cycling.
| Type | Receiver |
|---|---|
| Frequency | 900MHz |
| Power Supply | Battery |
| Features | Controls pool and spa functions |
| Power Source | Battery |