P/N 474131 Rev. M 8/2020 MasterTemp Pool and Spa Heater
43
SAFETY CONTROLS, (continued)
OPERATION OF IGNITION MODULE
The Ignition Module, (see Figure 43), is microprocessor based and operates on 24VAC supplied by the transformer. The
control utilizes a microprocessor to continually and safely monitor, analyze, and control the proper operation of the gas
ame holder. The module with the presence of the ame sensor, using ame rectication, allows the heater to operate.
WARNING
Diagnostic errors are displayed on
the control panel LCD: PS, HLS, SFS,
AFS, AGS, IGN, or NONE.
See Troubleshooting (page 51-53)
Flame Current
Check Point
Figure 43.
Diagnostic Indicator
(See table below)
Displayed Message Description
CONTROL FAULT Displays Message on Automation System
AIR FLOW FAULT Displays Message on Automation System
FLAME NO CALL FOR HEAT Displays Message on Automation System
IGNITION LOCKOUT Displays Message on Automation System
WEAK FLAME Displays Message on Automation System
and viewed on Heater menu
GOOD FLAME Displays Message on Automation System
and viewed on Heater menu
ERROR PS MESSAGE
The ERR PS message on the LCD indicates that there is insufcient water ow to the heater. If the pump is
operating, this usually indicates that the lter and/or skimmers should be cleaned (some lters may require
back-washing). If the message remains on after the lter/skimmers have been serviced, the system should be
checked by a qualied service technician.
RISK OF EXPLOSION OR FIRE CAUSING BURNS OR DEATH IF SAFETY INTERLOCKS ARE DISABLED. DO NOT attempt to operate
heater when The ERR HLS, ERR AFS, ERR IGN, ERR AGS, ERR SFS, E01, E05, E06, 126 messages on the LCD indicates a fault in the
heater or its controls. If any of these messages are displayed, shut down the heater (See “TO TURN OFF GAS TO THE APPLIANCE”
on page 41), and have a qualified service technician check the system.