21 21
ENGLISH
Refer to the “safety instructions.
   In normal conditions, the electric
pumps do not require any scheduled
maintenance.
   With a view to prevention of possible
faults, it is recommended to period-
ically check the pressure delivered
and current absorption. A reduction
in pressure is symptomatic of pump
wear. An increase in current absorp-
tion is symptomatic of abnormal
mechanical friction in the pump.
   Special maintenance may be required
to clean the pump and replace any
worn parts.
   If the pump is not used for prolonged
periods (e.g. for an entire season) it
should be drained completely rinsed
with clean water and stored in a dry
location.
At least twice a year, inspect the expansi-
on tank and check the pre-charge pres-
sure, sealing efficiency of the joints and
all areas for visible signs of damage and/
or corrosion. To check the pre-charge
pressure, turn off the pump and drain all
water from the system until the system
water pressure has returned to zero. On
completion of the check, restore the sys-
tem to normal conditions.
QUICK TROUBLE
SHOOTING GUIDE
Refer to the “safety instructions.
Water leaks from the air valve of the
expansion tank when checking the gas
pressure
   The membrane inside the tank is
damaged = replace the internal mem-
brane of the tank or replace the tank
itself
The pump does not work
   No power supply = turn on the switch
and check that no electrical connec-
tions are loose or defective.
   Check the mains voltage
   Fuse blown = check that the cables
and relative connections are not de-
fective and replace the fuse if neces-
sary
   The single phase motor thermal cut-
out has tripped = this is reset auto-
matically once the motor has cooled
   Motor overload cutout has tripped
= check that the cables and relative
connections are not defective, check
that the pump is not blocked mechan-
ically, or whether the pump winding is
damaged (replace if necessary)
   Electrical power line damaged =
replace
   Pump blocked mechanically = clean
   Control device faulty = replace pres-
sure switch
The pump stops after a short interval of
operation due to a tripped motor pro-
tection device
   Excessive current absorption = check
the operating condition of the pump
   If foreign bodies are present, block-
ing hydraulics = clean the hydraulic
components
   The single phase motor thermal cut-
out has tripped = this is reset auto-
matically once the motor has cooled;
check installation conditions