Pentax Spotmatic Spotmatic F Specifications

General IconGeneral
BrandPentax
ModelSpotmatic Spotmatic F
CategoryFilm Camera
LanguageEnglish

Summary

Introduction to the Honeywell Pentax Spotmatic F

Camera Nomenclature and Parts

Accessory Shoe and Hot Shoe

Location for attaching accessories like flashes.

Film Type Reminder Dial and Selector

Dial to remind film type and exposures.

Strap Rings

Attachment points for camera strap.

Stop-Down Lever and Metering

Lever for depth-of-field preview and metering.

Flash Terminals

Terminals for flash synchronization.

Depth-of-Field Controls

Lever and scale to check depth of field.

Diaphragm Ring and Scales

Ring to control aperture and view settings.

Distance Scale and Focusing Ring

Scale indicating focus distance and ring to focus.

Self-Timer Lever

Lever to activate the self-timer.

Shutter Speed Controls

Index and dial for setting shutter speed.

Film Speed Indicator

Indicator for film ISO/ASA setting.

Shutter Release and Lock

Button to activate the shutter and its lock.

Shutter Cocked Indicator

Indicator showing shutter is cocked.

Exposure Counter

Counter for number of exposures taken.

Internal Camera Components

Film Rewind Crank

Crank for rewinding film.

Film Transport Guides

Rails and rollers for film movement.

Viewfinder Eyepiece

Eyepiece for looking through the viewfinder.

Back Cover and Film Spool

Hinged cover, take-up spool, and film chamber.

Film Sprocket and Guides

Sprocket engaging film perforations and guide rails.

Shutter Curtain

Curtain that opens and closes to expose film.

Tripod Receptacle

Threaded hole for tripod mounting.

Battery Chamber

Compartment for camera battery.

Camera Specifications

Camera Type and Film Size

35mm single-lens reflex with TTL meter, 24x36mm picture.

Standard Lenses

Compatible SMC Takumar 50mm f/1.4 or 55mm f/1.8.

Shutter Details

Focal plane shutter, speeds B to 1/1000 sec.

Viewfinder and Focusing

Pentaprism finder with microprism, focus via distance scale.

Mirror and Lens Mount

Instant return mirror with shock absorbers, 42mm mount.

Film Advance and Cocked Indicator

Rapid wind lever and red disk indicator.

Additional Camera Specifications

Film Exposure Counter and Rewind

Automatic reset counter and rapid rewind crank.

Flash Synchronization

FP+X terminals and X contact on hot shoe.

Exposure Meter

TTL CdS meter, ASA 20-3200, powered by 1.3V battery.

Loaded Film Indicator

Dial indicates film type and exposures.

Camera Dimensions and Weight

Physical size and weight with/without lenses.

Basic Operating Instructions

Turn On Light Meter

Remove lens cap to activate meter circuit.

Set Film Speed

Set ASA dial to match film speed.

Set Shutter Speed

Set desired shutter speed on dial.

Compose and Focus

Focus subject using viewfinder and focusing ring.

Adjust Diaphragm for Exposure

Adjust diaphragm based on meter needle for correct exposure.

Release Shutter

Hold camera firmly and press shutter button.

Mercury Battery

How to Insert the Battery

Insert battery with (+) side outward.

Checking Battery Power

Check battery power by meter needle in viewfinder.

Battery Handling Cautions

Handle battery carefully, do not recharge or incinerate.

Film Loading and Winding Procedures

Opening the Camera Back

Open camera back by pulling rewind knob.

Loading the Film Cassette

Insert cassette and film leader into spool.

Advancing the Film

Advance film to engage sprockets and close back.

Confirming Film Loading

Confirm film movement by checking rewind knob.

Making Initial Blank Exposures

Make blank exposures until counter shows '1'.

Setting the Film Type Reminder Dial

Using the Film Type Dial

Set dial for film type (B&W, color) and exposures.

Checking if Film is Loaded

Turn rewind knob; free turn means no film loaded.

Setting the ASA Film Speed

Matching ASA Dial to Film Speed

Set ASA dial on shutter speed dial to match film.

Composing and Focusing

Achieving Sharp Focus

Focus until subject is sharp in microprism.

Understanding the Microprism

Microprism shows sharp image when focused.

Shutter Operation

Setting Shutter Speed

Set shutter speed before or after cocking.

Bulb (B) Mode for Long Exposures

Shutter stays open while button is pressed for 'Time'.

Shutter Cautions

Use tripod for slow speeds; protect shutter mechanism.

Camera Holding Techniques

Horizontal Shooting Position

Hold firmly with left hand, arms close.

Vertical Shooting Positions

Hold to forehead with left hand, adjust arm positions.

Film Unloading Procedure

Rewinding the Film

Rewind film into cassette using rewind crank.

Removing the Film Cassette

Open back cover and remove film cassette.

Stop-Down Lever and Metering

Normal 'Down' Position

Use 'down' for open-aperture readings.

When to Use 'Up' Position

Use 'up' for depth of field and close-up accessories.

Specific Takumar Lenses

List of Takumar lenses requiring stop-down metering.

Using Stop-Down Metering Lenses

Use 'Takumar' lenses for stop-down metering.

Performing Stop-Down Metering

Focus, push stop-down lever, center meter needle.

Depth-of-Field Preview Lever

Setting the Preview Lever

Set lever to 'AUTO' for Spotmatic F operation.

Model-Specific Operation

Lever operation specific to certain Pentax models.

Understanding Depth-of-Field

Definition of Depth of Field

Range of distances in focus at a given aperture.

Using the Depth-of-Field Guide

Use guide with distance scale for depth assessment.

Depth-of-Field Table: SMC Takumar 50mm Lens

Using the Self-Timer

Setting the Self-Timer Delay

Sets shutter release delay from 6-12 seconds.

Operating the Self-Timer Release

Use self-timer release button, not shutter button.

Exposure Metering Range

Meter Measurement Basis

Meter measures ground glass brightness.

Interpreting the Reading Range

Area 'A' indicates reading range, not total camera range.

Flash Synchronization

Flash Connection Terminals

FP/X terminals and hot shoe for flash sync.

Hot Shoe Flash Usage

Connects shoe-mount flash directly to hot shoe.

Hot Shoe Activation

Hot shoe activates with shoe-mount flash only.

Infra-Red Photography Guide

Using the Infrared Index

Use infrared index marked 'R' on depth-of-field guide.

Adjusting Focus for Infrared

Match subject distance to infrared index for focus.

Multiple Exposure Technique

Preparing for Multiple Exposures

Make first exposure, cock shutter without advancing film.

Completing Multiple Exposures

Make second exposure, then one blank for overlap.

Special Cautions for Use

Accessory and Lens Compatibility

Use only Takumar lenses and Pentax accessories.

Lens Cap Usage

Keep lens covered when not measuring light.

Integral Meter and Accessories

Meter works with accessories; no exposure factors needed.

Tripod Screw Length

Tripod screw length must not exceed 4.5mm.

Warranty Policy

Pentax International Warranty

Obtain international warranty card for foreign use.

Honeywell Service Centers