CT/L-14 Controller
3
Dear Customer!
Thank you for purchasing a controller manufactured by PERCo.
Please follow the instructions given in the Manual carefully,
and this quality product will provide many years of trouble-free use.
This Operation Manual for the CT/L-14 Controller (hereinafter – the Manual) provides information
on operation, installation, maintenance, storage and transportation of the CT/L-14 controller. The
Manual aims to provide correct operation of the controller and complete use of its technical
capabilities. The Manual contains data on installation and maintenance, and also a reference
section.
The Manual is active together with Technical description of PERCo-Web and also with certificates
of devices connected to the controller.
Abbreviations adopted in the Manual:
• ACM – access control mode;
• ACS – access control system;
• LAN
– local area network;
• OD – operating device;
• PS – power supply;
• RC– remote control;
• RTC – real-time clock;
• WRC – wireless remote control.
1 APPLICATION
CT/L-14 Controller (hereinafter – the controller) is a part of PERCo-Web ACS.
Attention!
The internal memory of the controller features special PERCo-Web
Software version,
allowing arranging ACS based on this controller, without a server on a separate PC.
In order to start operating the embedded ACS, t
he administrator is to use the system
manager, to do so, enter the controller Web-interface using computer via Ethernet
(Appendix 4, p. 2) and in browser address bar add the port number:49000 to controller IP-
address (login-password for initial entering: admin-admin). After this Web-
server and
system server are to be initiated. For the future enters one can only enter the controller
Web-interface and add the port number (initially :8080) to controller IP-address in browser.
When entering the system for the first time, the user will be requested to create login-
password pair for sanctioning subsequent system entrances.
The capabilities of PERCo-Web embedded security system are limited
1
.
Software licensing order, settings, characteristics and operation algorithm is described in
details in the operational documentation for PERCo-Web system. The current version of
the files is available in electronic format on the PERCo web-site: www.perco.com, in
Support > Downloads section.
The controller supports connection of (Sect. 5.6): up to 8 different PERCo readers with interface RS-
485, up to eight Wiegand readers using four AC-02.1 converters, and enables to organize up four
one-way or two-way passages.
Depending on the configuration (Appendix 4, p. 4) the controller can control the following ODs:
• up to four electromagnetic or electromechanical locks that support one-way or two-way
passage;
• up to two turnstiles or gates;
1
Embedded PERCo-Web system limitations: number of employees – up to 500, visitors – up to 500,
departments – up to 100, events – up to 1 mln, maximum number of controllers in the system – 10. Use
PERCo-Web access control system that can be installed on a separate server for a wider range of options.