INSTALLATION MANUAL
Service Instructions
18 North Dollins Ave, Orlando, FL 32805 Tel/Fax: 855-996-6900
nspdevelopment.com
OZONE BULB REPLACEMENT
The Ozone Bulb assembly should be replaced every
36 months -EVEN IF IT IS STILL OPERATIONAL.
The Ozone Bulb assemby has been made so that
anyone can replace these easily and quickly.
Turn off circuit breaker that supplies power to
the Ozone Generator.
1.
2.
3.
4.
Disconnect the 4 wire connector so that
you have 2 halves.
Remove the hose from each end of the ozone bulb assembly.
Final step is to push down on the middle of each clamp until they clamps union comes apart. You will have
to do each clamp individually. The Ozone Bulb assembly is now removeable from can assembly.
5.
Insert new ozone bulb assembly and reinstall going from steps 4 to 1.
TROUBLESHOOTING GUIDELINES
There can be only 3 areas to check if you think your Perfect Pool PP2 or PP3 is not operating correctly: The Ozone
Generator air pump (1) - the ozone bulb assembly (2) or the Ozone Diffuser
1.
In most all cases utilizing a small vial of Phenol Red dye (#2) available at any pool store or store selling pool chemicals.
Pheno Red is used to test swimming pool Ph.
The first thing to check is to ensure that power is going to the Ozone Generator unit.
2.
4.
3.
To check for proper operation off these units - open lid assembly and pour in Phenol Red
solution.
If unit is operating correctly - you will see a PURPLE dye coming from the Perfect Pool return wall fitting in
pool. This verify's that the air pump is working - air hose is connected and clear - diffuser is clean enough for
bubble operation AND that the ozone bulb is still prodoucing ozone as it's oxidized the Phenol Red to purple.
If Phenol Red enters pool still RED in color this is an indication that the Ozone Bulb needs replacing -
replace per instruction and rerun Phenol Red test to verify proper operation.
6.
5.
Upon opening of In Deck Filter assembly and there is no bubbles being generated then there check to ensure
power is on - air pump is operating and air tubing is still connected between Ozone generator and Filter. If
not identify where problem is and repair. Contact Customer Service for additional information.
Always check Ozone Diffuser & Filter anytime there is low flow rate coming back into pool. Clean as
neccessary to achieve correct flow rate.