EasyManua.ls Logo

Perkin-Elmer STA 6000 - User Manual

Perkin-Elmer STA 6000
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
STA 6000
Installation and Hardware
Guide
THERMAL ANALYSIS

Table of Contents

Questions and Answers

Summary

Introduction to STA 6000

Pyris Installation Guide

Install Multiple Analyzers

Guidance on connecting multiple instruments to the computer via USB.

Safety and Regulatory Information

Symbols Used in this Help

Explanation of text formatting and symbols used in the manual.

Notes, Cautions and Warnings

Explanation of how notes, cautions, and warnings are presented.

Symbols Used on the Instruments

Description of graphic symbols found on the instrument.

Electrical Warnings

Important electrical safety precautions and guidelines.

Electromagnetic Compatibility (EMC)

Information on EMC standards for Europe, South Korea, and the USA.

Electrical Safety

Details on conformity with IEC standards and low voltage directive.

WEEE Instructions for PerkinElmer Products

Guidelines for the disposal of electrical and electronic equipment.

Prepare the Laboratory

Electrical Requirements

Specifications and guidelines for the power source and line voltage.

Environmental Requirements

Conditions required for the laboratory environment, including temperature and humidity.

Purge Gas and Pneumatic Supply Requirements

Details on the recommended purge gas and its supply requirements.

Space Requirements

Information on the physical space needed for the instrument installation.

System Installation and Setup

Install Multiple Analyzers

Guidance on connecting multiple instruments to the computer via USB.

To install an EdgePort

Step-by-step instructions for installing the EdgePort USB converter.

Install an STA 6000

Step-by-step instructions for installing the STA 6000 analyzer.

Safety Precautions for the STA 6000

Crucial safety measures to be observed before and during STA 6000 use.

Important Specifications

Key technical specifications for the STA 6000 instrument.

Decontamination and Cleaning

Procedures for cleaning and decontaminating the instrument.

STA 6000 Warning Labels

Identification and explanation of warning labels on the STA 6000.

Unpacking the STA 6000

Instructions for safely removing the STA 6000 from its packaging.

Parts Included

List of components and accessories included with the STA 6000.

Set Up the STA 6000 System Components

Steps to set up the various components of the STA 6000 system.

Select the Correct Voltage for the STA 6000

Procedure to select and set the correct operating voltage for the STA 6000.

Connect the Purge Gas Supply to the STA 6000

Connecting the purge gas lines to the STA 6000 analyzer.

Connect the Cooling Device to the STA 6000

Steps to connect the cooling system (chiller) to the STA 6000.

Connect the STA 6000 Components

Procedure for connecting the STA 6000 to the computer and other peripherals.

System Configuration and Calibration

Configure the STA 6000

Configuring the Pyris software for the STA 6000 application.

Calibrate the STA 6000

Procedures for calibrating the STA 6000 for accurate measurements.

Weight Calibration

Steps to perform weight calibration on the STA 6000.

Weight Verification

Procedure to verify the accuracy of the weight calibration.

Sensor Calibration

Steps for calibrating the instrument's sensor.

DTA Baseline Optimization

Optimizing the DTA baseline for accurate measurements.

Temperature and Heat Flow Verification

Verifying temperature and heat flow accuracy using standards.

STA 6000 Hardware Overview

STA 6000 Hardware Overview

Comprehensive overview of the STA 6000 hardware components and features.

Sample Preparation

Instructions and guidelines for preparing samples for analysis.

Sample Pans

Information on the types and requirements of sample pans.

Sample Atmosphere

Controlling and managing the gas atmosphere for sample analysis.

Loading the Sample into the STA 6000

Step-by-step guide for loading samples into the instrument.

Cleaning the Furnace and Sample Holder

Procedure for cleaning the furnace and sample holder.

Cleaning the Cover

Procedure for cleaning the instrument cover.

STA 6000 Part Numbers

List of part numbers for ordering supplies and replacement parts.

AS 8000 Autosampler

AS 8000 Autosampler Overview

Overview of the AS 8000 autosampler accessory and its capabilities.

Safety Precautions for the AS 8000

Safety measures specific to the AS 8000 autosampler.

How the AS 8000 Autosampler Works

Explanation of the operational cycle and functions of the AS 8000.

Autosampler Work Cycle

Detailed description of the autosampler's work cycle for sample analysis.

AS 8000 Autosampler Gripper Alignment

Procedure for aligning the autosampler's gripper mechanism.

AS 8000 Sample Handling

Procedures for sample preparation and loading with the AS 8000.

Sample Preparation

Instructions for preparing samples for use with the AS 8000.

Sample Pans

Information on sample pan types compatible with the AS 8000.

Sample Loading

Procedure for loading samples into crucibles and trays.

Running a Play List with the AS 8000

Steps for creating and running sample analysis sequences.

Troubleshooting

Error Messages from the STA 6000

List of error messages and corrective actions for the STA 6000.

AS 8000 Autosampler Maintenance

Cleaning and Decontamination

Procedures for cleaning and decontaminating the AS 8000 autosampler.

Perkin-Elmer STA 6000 Specifications

General IconGeneral
BrandPerkin-Elmer
ModelSTA 6000
CategoryAnalytical Instruments
LanguageEnglish