1. Stop the engine and allow the engine to cool.
Loosen the cooling system filler cap slowly to
relieve any pressure. Remove the cooling system
filler cap.
Illustration 51 g06675854
Drain plug option
Note: Refer to Operation and Maintenance Manual,
“General Hazard Information” for information on
Containing Fluid Spillage.
2. Open the cooling system drain valve (if equipped).
If the cooling system is not equipped with a drain
valve, remove one of the drain plug (1).
Allow the coolant to drain into a suitable container.
NOTICE
Dispose of used engine coolant or recycle. Various
methods have been proposed to reclaim used cool-
ant for reuse in engine cooling systems. The full distil-
lation procedure is the only method acceptable by
Perkins to reclaim the coolant.
M0132847 83
Maintenance Section
Coolant (Commercial Heavy-Duty) - Change