PROBLEM CAUSE SOLUTION
Probe failure.
Refer to
Table 8-21 for resistance values. Re-
place probe if needed. See Section 8.6.4.
Probe is not connected to the control.
Reconnect probe. See
Section 8.6.4.
Refrigerator is too warm.
(continued)
Air Inltration
Sealing compound does not form a com
-
plete seal.
Refer to
Section 7.1.
Door gasket is damaged or out of place.
Refer to
Sections 7.1 and 9.5.
Condensate drain line/air trap is not
positioned properly.
Reposition in loop. See
Figure 7-3.
Refrigerator is too cold.
Incorrect control settings.
Return to factory settings.
See
Section 8.6.
Probe failure.
Table 8-21 for resistance values. Replace
probe if needed. See Section 8.6.4.
Control failure. Refer to Electrical System
Refrigerator runs continu
-
ously.
Condensing coil is dirty. Clean with soft brush and vacuum.
Incorrect control settings.
Return to factory settings.
See
Section 8.6.
Probe failure.
Table 8-21 for resistance values. Replace
probe if needed. See
Section 8.6.4.
Evaporator coil has iced over.
Remove ice per
Section 7.4.
Sealing compound does not form a com
-
plete seal.
Refer to
Section 7.1.
Door gasket is damaged or out of place.
Refer to
Section 7.1 and 9.5.
Condensate drain line/air trap is not posi
-
tioned properly.
Reposition in loop. See
Figure 7-3.
Extreme ambient conditions.
Refer to
Section 7.8.
Return to Table of Contents
Residential Refrigeration
and Front Venting Commercial Refrigeration
Service Manual
Troubleshooting Guide - Refrigeration System Page 3-2

Table of Contents

Other manuals for Perlick ADA-COMPLIANT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Perlick ADA-COMPLIANT Series and is the answer not in the manual?

Perlick ADA-COMPLIANT Series Specifications

General IconGeneral
BrandPerlick
ModelADA-COMPLIANT Series
CategoryRefrigerator
LanguageEnglish

Related product manuals