TDP072d+e.doc Rev.07.07.2015 Seite‐Page46/64
PerrotREGNERBAUCALWGmbHIndustriestraße19‐29/D‐75382Althengstett/Germany
Telefon:0049‐7051‐162‐0/Fax:0049‐7051‐162–133
E‐mail:perrot@perrot.de/E‐mailKonstruktion:technik@perrot.de
Seasonaladjust/WaterBudget
3. Toaccessthemenu,turnthemaindialtoBudget.
4. and will increase/decreasethepercentageofadjustment.Min.20%;Max.200%.
Setup
Thefollowingfunctionsmaybeselectedandsethere:
3. TurnthemaindialtoSetup.
4. Press or tomakeaselection.Theprogramselectedwillbeflashing.Press to
confirm.
A1:Rainsensor
Factorysetting=norainsensorconnected.
Pleasemakesuretoconnectrainsensorasperwiringdiagram4.2.
Pleasecheckwhetheryourrainsensorisanormallyclosed(N.C.)ornormallyopened(N.O.)
contact.
Press and tomakeaselectionandconfirmwith .
A2:KeySwitch
Pleasemakesuretoconnectkeyswitchasperwiringdiagram4.2.
Select“Rainsensor”byusingthe
and buttons.
Use and tonavigateto“Key”andpress toconfirm.
Note:
TurningthekeyswitchwillimmediatelystartPrg.A
BUTonlyifthemaindialisnotturnedto“SYSTEMOFF”
Externalprogramstartscanbestoppedbyturningthe
keyswitchonemoretime.