Troubleshooting
030113RDH 27
N: 15xxx\15700-0004.docx
3/1/2013
OCS OVERCURRENT SENSOR
Infield Adjustment:
1. If the current adjustment dial is calibrated, adjust it to the full-load amperage of the motor. If
it is not calibrated, turn the current adjustment dial to its lowest position.
2. Place the maximum load on the carriage.
3. Run the carriage UP.
4. If the solid state IOL trips, turn the current adjustment dial clockwise a small amount and
repeat step 3.
5. If the solid state IOL does not trip, run the carriage DOWN.
6. If the solid state IOL trips, turn the current adjustment dial clockwise a small amount and
repeat step 5.
7. If the solid state IOL does not trip, run the carriage UP and DOWN several times.
8. If the solid state IOL trips, repeat step 3.
9. If the solid state IOL does not trip, the solid state IOL is properly adjusted.
Note: This photo is for reference only. Your actual solid state OCS may be different.