18
The induction hob
or a cooking zone
has turned itself off
unexpectedly, a
tone sounds and an
error code is
displayed (typically
alternating with
one or two digits in
the cooking timer
display).
Please note down the error
letters and numbers, switch
the main power off and contact
customer service.
8. Failure Display and Inspection
The induction hob is equipped with a self-diagnostic function. With this test the
technician is able to check the function of several components without
disassembling or dismounting the hob from the working surface.
Please do not disassemble the unit by yourself to avoid any dangers and
damages to the induction hob.
Troubleshooting
1) Failure code occur during customer using & Solution;
Supply voltage is above the
rated voltage.
Please inspect whether power
supply is normal.
Power on after the power
supply is normal.
Supply voltage is below the
rated voltage.
High temperature of ceramic
plate sensor .(1#)
Wait for the temperature of
ceramic plate return to normal.
Touch “ON/OFF” button to
restart unit.
High temperature of ceramic
plate sensor .(2#)
High temperature of IGBT .(1#)
Wait for the temperature of
IGBT return to normal.
Touch “ON/OFF” button to
restart unit.
Check whether the fan runs
smoothly; if not, call customer
service.
High temperature of IGBT.(2#)
Ceramic plate temperature
sensor failure- -short circuit.
(F3 for 1#,F6 for2#)
Stop using the induction hob,
switch off the main power and
contact Customer Service.