EasyManua.ls Logo

Philips 160VW9FB/78 - Environmental Conditions (Mechanical)

Philips 160VW9FB/78
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HUDSON 9
71
Temperature
-20°C ~ + 60°C
Relative Humidity 5% ~ 85%
Absolute Air Humidity 1 ~ 25 g/m
3
Max. Change of Temperature
0.5°C/min. (max. 10°C/30min.)
Air pressure 700~1060 mbar (70~106Kpa)
Radiation Solar heat 700 W/m
2
Transport (according to IEC 721 / EN 60721 Class 2K2): (packed for a short time*)
Temperature
-20°C ~ + 60°C
Relative Humidity 15% ~ 98%
Absolute Air Humidity 1 ~ 32 g/m
3
Max. Change of Temperature Air/Air
-25°C/+25°C
Air Pressure 700mbar (70Kpa) max not relevant
Radiation Solar heat 700 W/m
2
Dewing Allowed
* Test condition: 16h with –25°C and 72h with +70°C (Ambient tem. + sunshine)
8.2 Environmental Condition (mechanical)
8.2.1 Operating (according to IEC 721/EN60721 Class (3M2))
Test Procedure IEC 68/EN 60068
Freq. range Hz 10~30 30~200 200~500
Change db/oct +12 -6
Spectral acceleration density m
2
/s
3
0.75
Accel. RMS m/s
2
4.3
Axis - 3
Vibration
(random vibration)
IEC 68-2-64
EN 60068-2-64
Duration/Axis Minutes 30
Pulse Half-sine
Acceleration m/s
2
50
Duration ms 6
Shock
IEC 68-2-27
EN 60068-2-27
Number 50 per relevant direction and function
http://www.wjel.net