EasyManua.ls Logo

Philips 32PFL3605/60 - Alignments

Philips 32PFL3605/60
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alignments
EN 18 TPM4.1E LA6.
2011-Jan-21
6. Alignments
Index of this chapter:
6.1 General Alignment Conditions
6.2 Hardware Alignments
6.3 TV Mode display adjust
6.4 PC mode display adjustment
6.5 Gamma upload and V-com adjustment
6.6 Option Settings
6.7 Serial Number Definition
Note: The Service Alignment Mode (SAM) are described in
chapter 5. Service Modes, Error Codes, and Fault Finding
.
Menu navigation is done with the CURSOR UP, DOWN, LEFT
or RIGHT keys of the remote control transmitter.
6.1 General Alignment Conditions
Perform all electrical adjustments under the following
conditions:
Power supply voltage: 195 - 264 V
AC
, 50/60 ± 3 Hz.
Connect the set to the mains via an isolation transformer
with low internal resistance.
Allow the set to warm up for approximately 15 minutes.
Measure voltages and waveforms in relation to correct
ground.
Caution: It is not allowed to use heatsinks as ground.
Test probe: R
i
> 10 M, C
i
< 20 pF.
Use an isolated trimmer/screwdriver to perform
alignments.
6.2 Hardware Alignments
Not applicable.
6.3 TV Mode display adjust
6.3.1 White balance adjustment
Equipment Requirements:
Quantum Data Pattern Generator 801GD or 802G or 802R;
Apply 720P/60 at the pattern TVBAR100.
Alignment method:
Set Smart picture as “personal” (Brightness = 50,
Contrast = 50, Video contrast = 50, Colour = 50); Access to
SAM first, then to enable AUTO_COLOR to get HD ADC
OFFSET and HD ADC GAIN. Check whether 32 gray scales
are distinguishable.
6.3.2 Colour Temperature Alignment
Apply full white pattern, select smart setting to be Personal
(Brightness = 50, Contrast = 50, Video contrast = 50, and
Colour = 50). Adjust SCALER GAIN R G B to reach W/D and
luminance in SAM mode as below.
Select Color Temp in the SAM OSD. The 1931 CIE
chromaticity (X, Y) coordinates must be adjusted
according to Table 6-1
.
Table 6-1 Reading with Minolta CA-110
If you do not have a colour analyser, you can use the default
values. This is the next best solution. The default values are
average values coming from production.
Select a COLOUR TEMPERATURE (e.g. COOL,
NORMAL, or WARM).
Set the RED, GREEN and BLUE default values according
to the values in Table 6-2
When finished press OK on the RC, then press STORE (in
the SAM root menu) to store the aligned values to the NVM.
Restore the initial picture settings after the alignments.
Table 6-2 White tone default settings
Luminance >400 cd/m
2
in the centre of the screen when “stand”
picture at contrast 50, Video contrast 50 and brightness 100,
with temp color “cool”.
Note: This group setting about colour temp is also applied in
TV/EX1/EX2/EXT3/VGA/HDMI/HDMI SIDE/AV SIDE. It means
that TV/EX1/EX2/EXT3/VGA/HDMI/HDMI SIDE/ AV SIDE use
one same setting.
6.4 PC mode display adjustment
6.4.1 AUTO colour adjustment
Set Brightness 100, Contrast 50, and apply 1024 × 768 @
60Hz mode with 50 Black and 50 White pattern at the factory
mode.
Activate AUTO-COLOR function for auto ADC offset and gain
setup. See Figure 6-1
.
Figure 6-1 50-Black 50-White
6.5 Gamma upload and V-com adjustment
6.5.1 Gamma Upload
Press Remote control “123789+Info” Key, Gamma data will be
load in IC MAX9668ETP by FW
Picture Temp x y
Normal 0.287 0.005 0.296 0.005
Cool 0.276 0.005 0.282 0.005
Warm 0.313 0.005 0.329 0.005
Picture mode
Screen
size
Colour temperature
Red Green Blue
Normal 32" 127 124 119
42" 127 126 113
Cool 32" 119 114 127
42" 125 121 127
Warm 32" 127 114 73
42" 127 118 72
18870_209_100209.eps
100308