Mechanical Instructions
EN 23QM15.2E LA 4.
2015-Sep-30
back to
div.table
4.4.2 AmbiLight Panel
Refer to Figure 4-24
for details.
1. Gently release the clamps and unplug the two connectors
[4] that secure the ambilight panels. Release the clips from
the FFC connector that connect with the Keyboard control
panel [5].
2. Lift the AmbiLight panel from the rear cover. Make sure that
wires and flat foils are not damaged while lifting the
Ambilight panel from the rear cover.
Figure 4-24 Ambilight and Keyboard removal
4.4.3 Keyboard Control Unit
Refer to Figure 4-24
for details.
1. Release the connector [2] from the SSB Board, then
release the connectors [3] from the Ambilight panel.
Caution: be careful, as these are very fragile connectors!
2. Remove all the fixation screws from the keyboard control
panel [1] and take it out from the Back cover.
When defective, replace the whole unit.
4.4.4 Small Signal Board (SSB)
Refer to Figure 4-25
for details.
Caution: it is mandatory to remount all different screws at their
original position during re-assembly. Failure to do so may result
in damaging the SSB.
1. Release the clips from the LVDS connector that connect
with the SSB[1].
Caution: be careful, as these are very fragile connectors!
2. Unplug all other connectors [2] .
3. Remove all the fixation screws from the SSB [3].
4. The SSB can now be shifted from side connector cover,
then lifted and taken out of the I/O bracket. Refer to
Figure 4-25
for details.
Figure 4-25 SSB removal