Mechanical Instructions
EN 17QM16.4E LA 4.
2016-Apr-1
back to
div.table
4.4.2 AmbiLight Panel
Refer to Figure 4-12
for details.
1. Gently release the clamps and unplug the connectors [4]
that secure the ambilight panels. Release the clips from the
FFC connector that connect with the keyboard [5].
2. Lift the AmbiLight panel from the rear cover. Make sure that
wires and flat foils are not damaged while lifting the
ambilight panel from the rear cover.
Figure 4-12 Ambilight and Keyboard removal
4.4.3 Keyboard Control Unit
Refer to Figure 4-12
for details.
1. Release the connectors [2] and [3] from the keyboard
control panel.
Caution: be careful, as these are very fragile connectors!
2. Remove all the fixation screws from the keyboard control
panel [1] and take it out from the Back cover.
When defective, replace the whole unit.
4.4.4 Small Signal Board (SSB)
Refer to Figure 4-13
for details.
Caution: it is mandatory to remount all different screws at their
original position during re-assembly. Failure to do so may result
in damaging the SSB.
1. Release the clips from the LVDS connector that connect
with the SSB[1].
Caution: be careful, as these are very fragile connectors!
2. Unplug all other connectors [2] .
3. Remove all the fixation screws from the SSB [3].
4. The SSB can now be shifted from side connector cover,
then lifted and taken out of the I/O bracket. Refer to
Figure 4-13
for details.
Figure 4-13 SSB removal