Software upgrade
A. Preparation to upgrade software
1) Start the CD Burning software and create a new CD
project (Data Disc) with the following setting:
Label: DVP3XXX
File System: DVP3000K_13.BIN (for DVP3000K/13/75)
DVP3000K_69.BIN (for DVP3000K/69)
DVP3000K_93.BIN (for DVP3000K/93)
DVP3005_00.BIN (for DVP3005/00/05)
DVP3005_02.BIN (for DVP3005/02)
DVP3005_04.BIN (for DVP3005/04)
DVP3005_78.BIN (for DVP3005/78)
DVP3005K_78.BIN(.for DVP3005k/78)
DVP3005K_93.BIN(.for DVP3005k/93)
DVP3010_00.BIN (for DVP3010/00/05)
DVP3010_02.BIN (for DVP3010/02/04)
DVP3005K_69.BIN (for DVP3005K/03/13/69/75)
Label: _____ (No need the label name)
File System: DVP3000_51.BIN (for DVP3000/51)
DVP3005_69.BIN (for DVP3005/69)
DVP3500_37.BIN (for DVP3500/37)
DVP3005_94.BIN (for DVP3005/94)
DVP3007_94.BIN (for DVP3007/69/94)
Note: It is required capital letter for the Label name &
the File System name.
2) Burn the data onto a blank CDR
B. Procedure for software upgrade:
1) Power up the set and insert the prepared Upgrade
CDR.
2) The set will starts reading disc & response with the
following display TV screen:
Upgrade File DETECTED
Upgrade?
Press Play TO START
3) Press <OK> button to confirm, then screen will display :
Files coping…
UPGRADING…
3) The upgraded disc will automatically out when files
coping complete, then take out the disc.
4) About 1 minute later, the trace will automatically close
when upgrading complete.
C. Read out the software versions to confirm upgrading
1) Power up the set and press <system menu> button on
the remote control.
2) Press <1><3><7><9> button.
The software version and other information are display
on the TV screen as follows:
Version XX.XX.XX.XX (Main version)
SUB-VER XX.XX.XX.XX ( software version of
application software)
8032 XX.XX.XX.XX
Servo XX.XX.XX.XX (software version of Servo)
RISC XX.XX.XX.XX
DSP XX.XX.XX.XX
Region Code X
3-1
Caution: The set must not be power off during
upgrading, in that case the decoder board will
be damaged entirely.