EasyManua.ls Logo

Philips Dynalite DDBC1200 User Manual

Philips Dynalite DDBC1200
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DDBC1200
Overview
Single-phase supply – 100 - 240 VAC at 0.5A
12 individually controlled lighting driver channels – each
Broadcast
High output capacity – each of the 12 channels is capable of
driving the following:
DALI: max 80 drivers per channel or 300 total
DSI: max 100 drivers per channel or 375 total
0-10V: 50mA sink or source per channel
LED status indicators and override switches – for each of the
12 outputs
Powerful internal PLC – allows custom scripts to enable process
control based on conditional logic
Dry contact interface – factory settings enable this interface to
Many control options – device is controllable via a combination of
methods, including a serial control port, relay contacts, push-button
wall stations, infrared receivers and timeclocks
Signal Dimmer Controller
Read Instructions – We recommend that you read this guide prior
to commencement of installation.
Special Programming – Once powered and terminated correctly
this device will only operate in basic mode. If network terminations
are correct, a new Dynalite user interface turns all lighting channels
on from button 1 and off from button 4. Commissioning can only
begin once the full network has been tested. Advanced functions
are commissioned via Envision software. If commissioning services
are required, contact your local distributor.
Check Connections – Tighten all load-bearing screw connections,
as vibrations from transport can cause the terminal block screws to
loosen.
Power Sources – This device must only be powered by the supply
Output Circuits – The load on each circuit must not exceed the
or 50mA sink or source for 1-10V.
Mounting Location – Install in a dry, well-ventilated location.
Controllers may emit some mechanical noise. Take this into
account when deciding the mounting location.
Data Cable – Use screened, stranded RS485 data cable with three
twisted pairs. Segregate from mains cables by at least 300mm.
is connected to an energized device is live. Do not cut or terminate
live data cables.
Electrical Diagram
Supply:
100 – 240 VAC
0.5A
E
µ
P
N
L
DA+
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
CH10
CH11
CH12
DA-
+
V
E
D
+
D
-
G
N
D
S
h
i
e
ld
A
U
X
DyNet
RS485
2 x RJ12
CH1
DA+
DA-
DA+
DA-
DA+
DA- DA+
DA- DA+DA- DA+
DA-
DA+DA-
DA+
DA-
DA+
DA-
DA+
DA-
DA+DA-
D
A
L
I
1
-
1
0
V
D
S
I
D
A
L
I
1
-
1
0
V
D
S
I
D
A
L
I
1
-
1
0
V
D
S
I
D
A
L
I
1
-
1
0
V
D
S
I
D
A
L
I
1
-
1
0
V
D
S
I
D
A
L
I
1
-
1
0
V
D
S
I
D
A
L
I
1
-
1
0
V
D
S
I
D
A
L
I
1
-
1
0
V
D
S
I
D
A
L
I
1
-
1
0
V
D
S
I
D
A
L
I
1
-
1
0
V
D
S
I
D
A
L
I
1
-
1
0
V
D
S
I
D
A
L
I
1
-
1
0
V
D
S
I
Supplied by:
Question and Answer IconNeed help?

Do you have a question about the Philips Dynalite DDBC1200 and is the answer not in the manual?

Philips Dynalite DDBC1200 Specifications

General IconGeneral
BrandPhilips
ModelDynalite DDBC1200
CategoryController
LanguageEnglish

Summary

Product Overview and Features

Single-Phase Power Supply

Device operates on a single-phase supply ranging from 100-240 VAC at 0.5A.

Lighting Driver Channels

Features 12 individually controlled channels, configurable for 1-10V, DSI, and DALI Broadcast.

High Output Capacity

Each channel supports DALI (80 drivers/300 total), DSI (100 drivers/375 total), or 0-10V (50mA).

Status Indicators and Controls

Equipped with LED status indicators and override switches for each of the 12 outputs.

Internal Programmable Logic Controller (PLC)

Allows custom scripts for process control based on conditional logic.

Dry Contact Interface

Factory settings enable interface to transmit network identification information.

Multiple Control Options

Controllable via serial port, relay contacts, push-button stations, IR receivers, and timeclocks.

Electrical Diagram and Wiring

Power Input and Outputs

Diagram shows 100-240 VAC 0.5A supply and 12 output channels (CH1-CH12).

Data Network Connections

Illustrates DyNet RS485 connections (D+, D-, GND, +VE, AUX) and RJ12 ports.

Installation and Setup Procedures

Mounting and Load Calculation

Mount on DIN-rail; calculate loads to prevent overloading channels.

Power and Earthing

Connect single-phase 0.5A feed and ensure the device is earthed.

Data Cable Connections

Connect data cables as per diagrams; use specified cable types.

Auxiliary Dry Contact Input

Connect dry contact device between AUX and GND terminals for specific functions.

Troubleshooting Reset

Press service switch 3 times to reset all connected drivers to default settings.

Technical Specifications and Recommendations

Recommended Cable Type

Use Dynalite DYNET-STP-CABLE or equivalent shielded four twisted-pair cable.

Recommended Cable Color Coding

Details color coding for GND, +12VDC, DATA+, DATA-, and shield.

Product Specifications Summary

Covers supply, control outputs, capacity, terminals, user controls, serial port, and compliance.

Operating and Storage Conditions

Specifies operating temperature (0-40°C) and humidity (0-95%), and storage (-25-70°C, 0-90%).

Physical Dimensions and Weight

Device dimensions are 93x215x64mm, weighing 0.54kg.