Removal of the UI
. To remove the UI push the  snaps inside (indicated with the red arrows):
. Then unplug the cable.
Do not use a screwdriver, but pull it keeping the at cable and not the connector (some force is required)
. Click on the  snaps to remove the UI board protection.
,
. To re-mount the UI start keeping inserted rst the upper part of the cover, then push it.
Make sure the  snaps are properly closed
,
Removal of the Grinder
. Pull out the grinder assy
. Remove the electric connections
Removal of the Electrovalves
. For the upper EV pull outwards the valve holder.
. For the lateral EV take out the  screws, then remove the valve.