EasyManua.ls Logo

Philips FWD16 series - Service Test Program

Philips FWD16 series
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 - 1
N
Y
REPEAT
SHUFFLE
button pressed?
PLAY
button pressed?
N
Y
Display shows all
segments and flags
for checking open circuits.
see figure 1
DISPLAY TEST FACTORY RESET
VERSION
CHECK
MACROVISION
CHECK
Display shows BLANK
fig. 1
N
Y
Display shows
EEPROM is cleared and
default values are stored.
This test should be done at the
end of the production process
so that every set is customised
before leaving factory.
Software Version is
also display on the
TV screen.
FWD17_V0.02.21M.R3 :
The model number is FWD17.
Software version is V0.02.
Distination region is 21M.
Region code for DVD disc is Region 3.
Display shows
software version.
X:XX is the software version,
eg. U 0:02
FWD17_V0.02.21M.R3
N
Y
PLAY
button pressed?
STOP
button pressed?
Macrovision version
number is display on
the TV screen.
MV.05.01.28.01
To enter Service Test
program, hold
PLAY & STOP buttons
depressed while switch
the source to DISC.
U X:XX
SERVICE TEST PROGRAM
5 - 1

Related product manuals