EasyManua.ls Logo

Philips HO - User Manual

Philips HO
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Philips T5 VHO Extreme
Temperature System
Ideal for high-bay
applications without
climate control
T5 COLLECTION
This lamp is better for the environment because of
its reduced mercury content.All Philips ALTO
®
lamps give you end-of-life options which can simplify
and reduce your lamp disposal costs depending on
your state and local regulations.
Lower the costs of your ceilings
With the Philips T5 VHO Extreme Temperature System,
you can use T5 lamps in high-bay applications without
sacrificing light output due to hot or cold temperatures.
Provides high light output even in spaces without climate control
Lumen output is >90% from 65˚F to 170˚F (20˚C to 75˚C) due to amalgam technology
More light over the life of the lamp than a standard 400W HID system
*
Operates on existing electrical system
277V–480V input voltage range eliminates the need for rewiring
your electrical system
Reduce total cost of ownership (TCOO) when compared to a
standard HID 400W system
Reduced energy costssave up to 40 system watts
Reduced maintenance costsup to 75% longer lamp life
which extends
the relamping cycle
Reduced costs since less lamps are needed to meet lumen requirements
**
(*, ‡, , ** See page 2 for footnotes)
New P-5904-A T5 VHO Prod Bulletin.qxd:Layout 1 9/9/08 6:08 PM Page 1
Question and Answer IconNeed help?

Do you have a question about the Philips HO and is the answer not in the manual?

Philips HO Specifications

General IconGeneral
BaseE26
Voltage120V
CRI80
Bulb ShapeA19
Lumens800
Base TypeMedium Screw (E26)
DimmableYes
Color Temperature2700K

Summary

Lower the Costs of Your Ceilings

High Light Output in All Conditions

Provides high light output even in spaces without climate control, maintaining >90% lumen output from 65°F to 170°F.

Operates on Existing Electrical System

277V-480V input voltage range eliminates the need for rewiring your electrical system.

Reduced Total Cost of Ownership

Lower TCOO compared to standard HID 400W systems via reduced energy and maintenance costs.

Lamp Ordering, Electrical and Technical Data

Ballast Ordering, Electrical and Technical Data

Features

Highlights include programmed start ballast, 277V-480V input range, and a 194°F/90°C maximum case temperature.

General Specifications

Details on physical characteristics, performance requirements, regulatory compliance, and other manufacturer standards.

Wiring Diagram-Lamp Operation

Enclosure Dimensions

Related product manuals