52
ALTERNATING
CURRENT
MEASUREMENTS
WITH
CURRENT
TRANSFORMER
PM
9245
(Fig.
26,
page
150).
Select
function
A~
rms
with
the
function
selector.
Select
the
manual
or
automatic
ranging
mode
with
pushbutton
AUTO/MAN*
Remark:
Manual
rqpging
is
indicated
with
a
*
on
the
display.
In
automatic
ranging
mode
the
UP
level
is
2100
and
the
DOWN
level
is
0180.
Select
in
manual
ranging
mode
the
correct
range
with
pushbuttons
UP
or
DOWN.
Remark:
Available
ranges
are:
mA
terminal
0.2
A
—20
A
terminal
2.000
pA
200.0
mA
20.00
juA
2.000
A
200.0
pA
20.00
A
2.000
mA
20.00
mA
Only
ranges
200
mA
or
lower
are
being
used.
Overload
is
indicated
with
OL
on
the
display
(Display
>
2100).
Connect
the
current
transformer
PM
9245
to
the
PM
2521
as
shown
in
Fig.
26,
page
150.
Remark:
Before
measuring,
always
connect
the
current
transformer
to
the
PM
2521
first.
Avoid
contamination
of
the
core-parts.
The
transfer
factor
of
the
PM
9245
is
1000
(100
A
=
100
mA).
The
frequency
range
is
45
Hz
up
to
1
kHz.
As
the
high
current
measurements
with
the
PM
9245
are
made
in
the
A~
rms
function
of
the
PM
2521,
they
have
the
same
facilities
as
the
alternating
current
measurements.
Refer
to
Chapter
6.4.1.5.
6.4.2.3.
Data
hold
measurements
with
probe
PM
9263
(Fig.
27,
page
150).
GENERAL
With
the
data
hold
probe
PM
9263
the
data
on
the
display
can
be
freezed
while
measuring.
The
data
hold
mode
^s
valid
for
all
functions
except
the
s
functions.
In
the
s
function
the
data
hold
mode
switches
on
the
special
trigger
mode
(Refer
to
chapter
6.4.1.10).
DATA
HOLD
MEASUREMENTS
Connect
the
data
hold
probe
PM
9263
to
the
PM
2521
as
shown
in
figure
27,
page
150.
Select
the
desired
function
and
measuring
mode.
Connect
a
zero
lead
to
the
0
input
of
the
probe.
This
can
be
done
in
the
following
ways:
With
a
separate
banana-plug
lead
connected
to
the
"0"
input
of
the
probe.
This
lead
is
not
included
in
the
delivery
of
the
probe.
With
a
zeroing
clip-on
cable
supplied
with
the
probe
on
the
probe-tip.
Select
the
most
suitable
test
pin
for
the
probe-tip.
Push
the
slide
switch
(white
ring)
on
the
probe
in
position
RUNNING
(away
from
the
probe-tip).
Place
the
probe-tip
on
the
measuring
spot
and
measure
the
input
signal.
Push
the
slide-switch,
while
measuring
to
position
HOLD
(towards
the
probe-tip).
The
data
on
the
display
is
now
held
(freezed).
Remark:
Only
the
data
on
the
display
is
held.
Meanwhile
the
PM
2521
continues
measuring.
The
maximum
voltage
between
probe-tip
Vfiand
0
is
30Vrms.