The Philips Respironics Detachable Battery Module can be used to power your BiPAP A40 device with a rechargeable Lithium-ion detachable
battery. When inserted into the module and connected to the device, the detachable battery will automatically recharge. See the instructions
included with the Detachable Battery Pack for more information on the detachable battery.
Cautions:
Do not open the Detachable Battery Module case. There are no user-serviceable parts inside.
Do not expose the Detachable Battery Module to water or conductive liquids; this is not a sealed case.
Use only with the lithium-ion batteries specied below. Other types of batteries may burst causing injury.
Note: For use only with Philips Respironics Lithium-ion batteries (1055804 and 1043570).
Connecting the Detachable Battery Module
To connect the battery module to the device and install the detachable battery, complete the
following steps:
1. Remove the side cover on the therapy device. Press in the tab on the side cover and pull the
cover away from the device.
2. Line up the Detachable Battery Module and the therapy device side by side, and make sure
the guides on the module t into the slots on the therapy device.
3. Press the two units together until they snap into place. Make sure the therapy device and
battery module are completely seated against each other.
4. Insert the detachable battery into the battery module as shown below, until it snaps into
place. Close the lid on the battery module.
Detachable Battery Module Specications
Specication Description
Weight 15 ounces
Dimensions 3.8” H x 3.9” W x 6.8” L (9.7 cm H x 9.9 cm W x 17.3 cm L)
Standards Compliance IEC 60601-1; IEC 60529; EMC: CISPR 11, EN 55022, EN 55024; EN 61000-3-3; IEEE 1625; FCC Part 15
Symbol Key
The following symbols appear on the battery module.
Symbol Description
Attention: Consult Accompanying Documents
Electrical Input
Electrical Output
Separate collection for electrical and electronic equipment per EC Directive 2012/19/EU.
English
REF 1096770
Detachable Battery Module
1097573 R10
KGP 10/04/2019
Manufactured for:
Respironics Inc.
1001 Murry Ridge Lane
Murrysville, PA 15668 USA
Respironics Deutschland GmbH & Co. KG
Gewerbestrasse 17
82211 Herrsching, Germany
Question and Answer IconNeed help?

Do you have a question about the Philips RESPIRONICS 1096770 and is the answer not in the manual?

Overview

The Philips Respironics Detachable Battery Module is designed to power your BiPAP A40 device using a rechargeable Lithium-ion detachable battery. When the detachable battery is inserted into the module and connected to the BiPAP A40 device, it will automatically recharge. For more detailed information on the detachable battery, refer to the instructions included with the Detachable Battery Pack.

Important Cautions:

  • Do not open the Detachable Battery Module case. There are no user-serviceable parts inside the module. Opening the case may void warranties or cause damage.
  • Avoid exposure to water or conductive liquids. The Detachable Battery Module is not a sealed case and exposure to such substances can lead to damage or malfunction.
  • Use only specified Lithium-ion batteries. It is crucial to use only Philips Respironics Lithium-ion batteries (models 1055804 and 1043570) with this module. Using other types of batteries may result in bursting, causing injury or damage to the device.

Connecting the Detachable Battery Module:

To connect the battery module to your BiPAP A40 device and install the detachable battery, follow these steps:

  1. Remove the side cover on the therapy device: Locate the tab on the side cover, press it in, and pull the cover away from the device. This exposes the connection port for the battery module.
  2. Align the module and device: Position the Detachable Battery Module and the therapy device side by side. Ensure that the guides on the module align and fit into the corresponding slots on the therapy device. This alignment is critical for a secure and proper connection.
  3. Secure the connection: Press the two units together firmly until they audibly snap into place. Verify that the therapy device and the battery module are completely seated against each other, forming a stable and integrated unit.
  4. Insert the detachable battery: As illustrated in the manual, insert the detachable battery into the battery module until it snaps securely into place. Once the battery is inserted, close the lid on the battery module to protect it and ensure it remains in position.

Technical Specifications:

  • Weight: Approximately 15 ounces (0.425 kg). This lightweight design contributes to the portability of the combined device.
  • Dimensions: 3.8 inches (9.7 cm) in height, 3.9 inches (9.9 cm) in width, and 6.8 inches (17.3 cm) in length. These compact dimensions ensure that the module integrates seamlessly with the BiPAP A40 device without adding excessive bulk.
  • Standards Compliance: The Detachable Battery Module complies with several international and regional standards, ensuring its safety and performance:
    • IEC 60601-1: General requirements for basic safety and essential performance of medical electrical equipment.
    • IEC 60529: Degrees of protection provided by enclosures (IP Code), indicating its resistance to dust and water (though it is not sealed against liquids).
    • EMC (Electromagnetic Compatibility): CISPR 11, EN 55022, EN 55024, EN 61000-3-3. These standards ensure that the device operates without causing or being susceptible to electromagnetic interference.
    • IEEE 1625: Standard for rechargeable batteries for portable computing.
    • FCC Part 15: Regulations concerning unintentional radiators, ensuring it does not cause harmful interference and accepts interference received.

Symbol Key:

The following symbols appear on the battery module to provide important information:

  • "i" (Information Symbol): Attention: Consult Accompanying Documents. This symbol indicates that users should refer to the provided manual for important instructions and safety information.
  • Electrical Input Symbol: This symbol denotes the port or area where electrical power is supplied to the battery module for charging.
  • Electrical Output Symbol: This symbol indicates the port or area where electrical power is delivered from the battery module to the connected device.
  • WEEE (Waste Electrical and Electronic Equipment) Symbol: This symbol signifies that the product requires separate collection for electrical and electronic equipment, in accordance with EC Directive 2012/19/EU. This promotes environmentally responsible disposal and recycling.

Usage Features:

  • Automatic Recharging: Once the detachable battery is inserted into the module and the module is connected to the BiPAP A40 device, the battery will automatically begin to recharge, ensuring it's always ready for use.
  • Seamless Integration: The design allows for a secure and flush connection between the battery module and the therapy device, creating a stable and compact unit.
  • Portability: The lightweight and compact design of the module, combined with the detachable battery, enhances the portability of the BiPAP A40 device, allowing for use in various settings.

Maintenance Features:

  • No User-Serviceable Parts: The module is designed without any internal components that can be serviced by the user, simplifying maintenance by eliminating the need for complex repairs.
  • Battery Replacement: The detachable nature of the battery allows for easy replacement if needed, extending the lifespan of the module and the BiPAP A40 device.
  • Environmental Disposal: The WEEE symbol guides users on the proper disposal of the electronic components, promoting recycling and reducing environmental impact.