Functions/features explanation
Duo select coee volume routine adjustment.
1. Unplug the appliance from the mains.
2. Press the 1-cup, ON/O button and 2-cup button simultaneously and plug the mains on.
3. When above step succeeded the led will turn on continuously.
4. Depending if the volume has to de- or increase you have to push the one- or two-cup button.
Every time you push the 1- or 2 cup button the LED will turn o for 0.5 second (feedback to user) and
the pump time will be shortened or lengthened for 0.6 seconds depending which button was pushed.
Pushing 1-cup button pump, time will be shorten with 0.6 sec is approximately - 4 cc/ml (less coee)
Pushing 2-cup button pump, time will be lengthen with 0.6 sec is approximately + 4 cc/ml (more coee)
The new value will be stored when you switch the appliance o by pushing the on/o switch.
(LED will turn o)
5. Turn appliance on again and brew one cup, measure the volume. In case the volume is not within
specication repeat steps 1 - 4.
Restoring the Boiler_empty ag to production default:
Sometimes it is needed, that the boiler of the SENSEO have to be emptied.
This for instance in wintertime were the possibility exists that the boiler becomes frozen during transport e.g.
For those occasions, it is handy to restore the Boiler_empty_ag again to production default.
Bringing the SENSEO back into production status, has the benet the ush routine will be activated
automatically when installed by the consumer.
How to SET the Boiler_empty_ag:
Keep the 1-cup button pressed while plugging in the power plug of the appliance in the mains socket.
The main switch LED will blink very rapidly for approximately 1 second.
To check if the Boiler_empty_ag is really set, reconnect the power plug to the mains a second time and
push the main switch. The main switch LED should light continuously.