7
To remove lever from lid cover, take a screwdriver
and bend carefully the two lips/ribs in the lid
cover outwards and push the lever with force out
of the hinge.
To reassemble, follow steps backwards, without
using a screwdriver.
To remove the brew chamber head assy, follow
below steps:
Remove the back cover.
Place the appliance in front of you in such a way
that you are facing the rear side of the appliance.
First remove the boiler from the snap lock
position of the brew chamber.
To remove the brew
chamber, use your both
thumbs (see picture 3)
and push strongly with a
little distortion (rotation)
until the brew chamber
comes loose (upwards).
Reassemble follow above steps backwards.
To reach the components placed inside the base
(for example exchange the NTC temperature
sensor) follow below steps:
First remove back cover, three-way valve and
boiler.
The brew chamber can be removed by
unhooking the two snap locks behind the boiler,
pull the brew chamber upwards to remove it
from the housing.
Remove both Torx T15 screws B (see exploded
view).
Unhook the two snap locks on the back side
of the base with a screwdriver (see base), the
housing can now be removed.
To remove the rest of the housing unlock the last
4 snap locks on the base and gently pull of the
front cover.
To reassemble follow above steps backwards.
picture 3