For example: program 1 – 8:30am to 8:30pm. Program 2 – 10:00pm to 10:03pm. Program 3 –
11:30pm to 11:33pm. Program 4 – 1:00am to 1:03am. Program 5 – 2:30am to 2:33am. Program 6 –
4:00am to 4:03am. Program 7 – 5:30am to 5:33am. Program 8 – 7:00am to 7:03am
When a program has the controller off, just the time will show on the display. If you think the controller
should be running, check to make sure there are not two programs overlapping each other.
CONNECTING YOUR SOLENOID
• Standard 24VAC Solenoids
• Simply strip wire jacket back approximately ¼” from end of both wires, (if not already done by
manufacturer).
• Insert 1 wire into #1 slot of solenoid plug (provided by Phytotronics) and the other wire into the #2
slot and tighten down firmly, BY HAND, with supplied Phytotronics screwdriver.
• 3 Wire 24VAC Solenoids
• Attach the 2 power wires just like a 2 wire solenoid into solenoid plug.
• The 3rd wire is a ground wire. (usually green or green with a yellow stripe) ground this wire properly
with all local, state, and national codes.
• 120VAC solenoids will not work directly with your Trident T3A. You must use some kind of 24VAC
interface between your Trident T3A and 120VAC solenoid. i.e. a 24VAC relay.
NOTE: Any attempt to bypass the 24VAC transformer to power this unit directly from a 120VAC power
source will damage the controller’s circuitry and render it unfit for use.
Such action will also void the Phytotronics warranty!
NOTE: Maximum controller output is 1 Amp.
FOR ANY TROUBLESHOOTING
PLEASE CONTACT PHYTOTRONICS @:
OFFICE: (314) 770-0717
EMAIL: repairs@phytotronics.com