EasyManua.ls Logo

Piazzetta MC 120/48 - User Manual

Piazzetta MC 120/48
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Riverside, Goods Road, Belper, Derbyshire. DE56 1UU
Tel: 01773 820940 Fax: 01773 820477
E-mail: info@robeys.co.uk Web Site www.robeys.co.uk
INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE
MC 70/51 MC 90/44
MC 120/48
Question and Answer IconNeed help?

Do you have a question about the Piazzetta MC 120/48 and is the answer not in the manual?

Summary

Supplementary Installation Instructions for the UK Market

Read Instructions Carefully

Instructions must be read carefully before installation.

CO Alarms

Requirement to fit a carbon monoxide alarm in the same room as the appliance.

Health and Safety Precautions

Measures to ensure Health and Safety at Work Act requirements are met during installation.

Stove Performance

UK approval by HETAS Ltd for intermittent operation with wood logs.

Preparatory Work and Safety Checks

Important warnings and checks before installation, including chimney and air supply.

Chimney Requirements

Details on chimney height, sound condition, and flue liners.

Hearth Requirements

Requirements for non-combustible hearths and clearance distances.

Combustion Air Supply

Ensuring adequate air supply into the room for safe and efficient operation.

Connection to Chimney

Methods for connecting the stove to masonry or prefabricated chimneys.

Electrical Services

Requirement for qualified electrician for electrical services installation.

Carbon Monoxide Alarm

Installation guidelines for CO alarms, compliance with BS EN 50292.

Commissioning and Handover

Post-installation checks, drying time, and customer advice.

Important Notes

CO Alarm

Installer should fit CO alarm; follow instructions if alarm sounds.

Use of Fireguard

Requirement for fireguard for safety with children or infirm persons.

Chimney Cleaning

Recommendations for chimney sweeping frequency and methods.

Clean Air Act and Smoke Control Areas

Information on UK Clean Air Act regulations for smoke control areas.

Fuel Overloading

Warning against overloading fuel to prevent excess smoke.

User Operating Instructions - Wood

HETAS Ltd Approval

HETAS approval limited to specific fuel types.

Recommended Fuels

Guidance on selecting and using dry, seasoned wood logs.

Door Operation

Procedure for safely opening and closing the stove door.

Lighting of Fire

Step-by-step guide for lighting the fire, including damper settings.

Maintenance

Refuelling

Guidelines for refuelling the firebox to maintain efficiency.

Flueway Cleaning

Importance of cleaning baffle plate and flueways regularly to prevent blockages.

Spare Parts

Information on obtaining spare parts from Robeys Limited.

Trouble Shooting

Guidance on resolving common stove operational issues and their remedies.

General Rules; Quick Guide

Minimum Safety Distances

Minimum clearances from stove to flammable walls, ceiling, and floor.

Flue Way Connection

Procedure and requirements for connecting the stove to the flue.

Domestic Fire Prevention

Measures to prevent domestic fires related to stove installation and use.

Technical Data and Specifications

Appliance Description

Overview of the compact MC stoves' design and features.

Appliance Features

Key features like fuel type, firebox material, and heating system.

Product Identification

Location and importance of rating and serial number plates.

Technical Specifications

Detailed technical data including heat output, flue diameter, and weight.

MC 70;51 Dimensions

Detailed dimensions for the Piazzetta MC 70/51 model.

MC 90;44 Dimensions

Detailed dimensions for the Piazzetta MC 90/44 model.

MC 120;48 Dimensions

Detailed dimensions for the Piazzetta MC 120/48 model.

Installation Procedures

General Installation Steps

Key steps for installing the stove, including unpacking and leveling.

Door Opening Mechanism

Instructions for changing the door opening direction.

Feet Kit Installation

Step-by-step guide for installing the adjustable feet kit.

Operating the Stove

Fuel Selection and Properties

Guidance on selecting and using dry, seasoned wood for optimal performance.

Combustion Air Regulation

How to adjust air dampers for optimal thermal efficiency and draught.

Fire Lighting Procedure

Step-by-step guide for lighting the fire, including damper settings.

Opening the Stove Door

Procedure for safely opening the stove door when lit.

Overheating and Fire Extinguishing

Actions to take in case of overheating or fire.

Maintenance and Cleaning

Periodic System Control

Regular checks of flueways, air intake, and appliance parts.

Ceramic Cladding Cleaning

How to clean the ceramic cladding using appropriate methods.

Grate Cleaning

Daily cleaning routine for the grate to maintain efficiency.

Ash Disposal

Safe methods for disposing of ashes.

Aluker Plate Removal

Instructions for removing the Aluker plates for cleaning or maintenance.

Troubleshooting Common Issues

Dirty Window Troubleshooting

Causes and remedies for a window becoming excessively dirty.

Condensation Issues

Causes and remedies for condensation forming in the flue or appliance.

Lighting Difficulties

Troubleshooting steps for problems with lighting the stove.

Smoke Emission Troubleshooting

Addressing smoke emission issues, especially in adverse weather.

Grate Not Warming

Troubleshooting for the grate not reaching adequate temperature.

Smoke Upon Door Opening

Causes and solutions for smoke appearing when opening the door.

Piazzetta MC 120/48 Specifications

General IconGeneral
BrandPiazzetta
ModelMC 120/48
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals