Specification
PTW-500 Color Code Sensor
Attention:
To ensure safety,please follow the below regulations when
using sensor:
1
、
This product only use for detecting object. Never use it as
a sensing device for personnel protection.
2
、
This product can’t be used as an explosion-proof
product.Please don’t use this product in hazardous place or
the place with potentially explosive gases.
3、This product input DC power, Prohibit use AC
power.Otherwise, it will cause product explosion and be on
fire
4、Please don’t wire the amplifier along with the power or
high-voltage lines,otherwise the sensor be damaged.
5
、
When using commercial switch voltage regulator,please
ensure frame ground terminal and ground terminal ground
connection.
6、Please don’t use this item outdoor or in the location where
external light can enter the receiving surface.
Model
PTW-500N PTW-500P
NPN output PNP output
Type 1 outputport,cable type
Control Output
1 outputport,includeshort circuitprotectionand
anti interferencefunction
Light Source whiteLED, adjustablespot, minimunspot size:
3.6MM
Response time AUTO,C and CI mode 200us, MARK mode
160us
Output option
LIGHT-ON/DARK-ON
Indicator
Operation indicator: RedLED、LED display
Detection Way:
AUTO,C and CI mode and MARK mode
sensing distance :30MM—500MM
Timer
OFF delay/ON delay/one shot/ ON delay one
shot,optional. Timer range (ms): 1ms ~
9999ms
Control Output
NPN/PNPopen collector24V,100mA or less(only
maincomponents)
Current consumption 40mA or less remaining
voltage:2V
Power Supply
12 ~ 24VDC±10%,ripple(P-P)10% or less,
Class 2
Ambient Light
Incandescent:20,000luxorless, Sunlight:30,000luxor
less
Power
Consumption
Voltage:24Vorless,
Cureent: 60MA or less
Voltage:24Vorless,
Cureent: 60MA or less
Vibration
Resistance
10 to 55Hz, doubleamplitude:1.5mm,2 hoursin
each of X,Y and z direction
Ambient
temperature
-10 to +55℃, no freezing
Circuit and Wiring Diagram
PTW-500N NPN
PTW-500P PNP
Setting
Under display menu
In MARK mode,two-point calibration: In MARK mode, STB C I
The STB in the indicator light will light up, C I indicator light off,
means it in the MARK color code state.
Step 1. Align the spot with the color code of workpiece and press SET
key, the screen will display SET1 and flash.
Step 2, move the spot to the background and press the SET button.
01