TONE DIAL should be a +
Check for other options that need to be activated as per your installation requirements.
When done press ENTER.
Next option is the NO. of RINGS and DIALS
Rings to be set as 1
Dials to be set as 3. When done press ENTER
Next option is the Ack Wait time and should be left as is. Press ENTER.
Next option is the External Line and should be left as is. Press ENTER.
Next option is communications method to be enabled. PSTN Primary should be + (positive)
and the rest – (negative). When done press ENTER.
Press END a few times to exit the programming.
Away arming and disarming via relay 1 (stay arming to be done via keypad only)
There is already an on-board key switch zone which only needs to be pulsed for the system
to arm. Connect the relay NO to the KEY connection on the alarm panel and the COM from
the relay to the negative/common on the alarm panel. No resistor required.