MODEL NUMBERS:
REM-45-KFA-O / REM-80T-KFA-O / REM-140T-KFA-O / REM-190T-KFA-O / REM-215T-KFA-O
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING: READ AND UNDERSTAND ALL OF THE
INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, STARTING,
OR SERVICING THE HEATER. Be sure to comply with the instructions and warnings provided with
this heater. Failure to comply can result in fire or explosion that can cause property loss, bodily injury,
or loss of life. Only persons who can follow and understand these instructions should operate or
service this heater. If you need heater info; such as an operating manual, labels, etcetera, contact
Remington at 866-676-1989.
DANGER
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED
SPACES WITHOUTADEQUATEVENTILATION. THIS HEATER IS
SUITABLE FOR OUTDOOR USE, AND INDOOR USE ONLY IN WELL
VENTILATED AREAS. INDOOR USE PERMITTED ONLY FOR: THE TEMPORARY HEATING OF
ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION, ALTERATION
OR REPAIR. This is an unvented portable heater that uses air (Oxygen) from within the area in which it
is used. Failure to provide adequate combustion and ventilation air will result in asphyxiation, carbon
monoxide poisoning, bodily injury or death. Refer to “Ventilation” on Page 6.
FACTORY ID: 500
DANGER
Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989
Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com
© 2021 Pinnacle Climate Technologies, Inc.
RGKJ-403
User’s Manual &
Operating Instructions
KEROSENE FORCED AIR
HEATER
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. For Example: 150812779.
Have your Serial Number ready before calling customer service at 866-676-1989.

Questions and Answers

  • M
    Marissa KingAug 3, 2025
    What to do if Pinnacle Climate Technologies Heater won't start and shows E1?
    • S
      Stephen FrancoAug 4, 2025
      If your Pinnacle Climate Technologies Heater won't operate, or the motor runs briefly with the lamp flickering and the LED display showing “E1”, there are several potential causes. Start by filling the tank with fresh kerosene if it's empty. Then, adjust the pump pressure if it's incorrect. Next, clean or replace the spark plug if it's corroded or has an incorrect gap. Also, clean or replace the fuel filter if it's dirty, as well as the nozzle. If there's moisture in the fuel tank, rinse it with clean, fresh kerosene. Inspect all electrical connections between the transformer and circuit board. Re-attach the ignitor wire to the spark plug if it's disconnected. Finally, replace the ignitor if it's defective, and adjust the rotor if the spacing is improper.
  • T
    Thomas BuchananAug 10, 2025
    How to fix poor combustion in Pinnacle Climate Technologies Remington REM-80T-KFA-O Heater?
    • T
      Timothy HesterAug 10, 2025
      If your Pinnacle Climate Technologies Heater is producing poor combustion or excess soot, it could be due to several factors. Try these solutions: * Clean or replace the air or lint filter if it's dirty. * Clean or replace the fuel filter if it's dirty. * Flush the fuel tank and refuel the heater with good quality fuel. * Ensure you are using the proper pressure. * Clean or replace the nozzle if it's dirty.
  • N
    nwagnerAug 16, 2025
    What to do if Pinnacle Climate Technologies Heater fan not working?
    • D
      Dr. Joseph HernandezAug 16, 2025
      If the fan in your Pinnacle Climate Technologies Heater doesn't operate when plugged in and the power switch is on, and the lamp is flickering or the LED display shows “E1” or “E2”, there are a couple of things you can check. First, if your model has a thermostat, make sure it isn't set too low by rotating it to a higher setting. Second, inspect all electrical connections between the main PCB and the motor to ensure they are properly connected.
  • K
    Kyle GomezAug 22, 2025
    Why Pinnacle Climate Technologies Remington REM-80T-KFA-O does not turn on?
    • T
      Tammy CampbellAug 22, 2025
      If your Pinnacle Climate Technologies Heater does not turn on and the lamp is not lit, it could be due to a few reasons. First, push the power switch to “OFF” and allow the heater to cool for 10 minutes if the temperature limit sensor has overheated, then restart the heater. Second, check the power cords for proper connection and test the power supply to ensure there is electrical power. Third, check or replace the fuse if it's blown.
  • S
    samuel11Oct 28, 2025
    Why does my Pinnacle Climate Technologies Remington REM-80T-KFA-O Heater ignite then shut off with an E1 error?
    • C
      Chris HansenOct 28, 2025
      If your Pinnacle Climate Technologies Heater ignites but the main PCB shuts off shortly after, with the lamp flickering and the LED display showing “E1”, it could be due to several reasons. First, adjust the pump pressure if it's incorrect. Second, clean or replace any dirty input, output, or lint filters. Third, clean or replace the fuel filter if it's dirty. Fourth, clean or replace the nozzle if it is dirty. Fifth, clean or replace the photocell lens if it's dirty. Sixth, adjust the photocell position if it's not installed properly. Seventh, replace the photocell if it is defective. Eighth, check the wiring connections between the main PCB and the photocell. Ninth, check the thermister placement if it's improperly located. Finally, replace the temperature limit switch if there's an impr...

Summary

Locating Your Serial Number

Safety Information

Whats in the Box

Specifications

Features

Assembly Instructions

Operation

Fueling The Heater

Instructions for safely fueling the kerosene heater with K-1 kerosene, including notes on fuel storage.

Ventilation

Guidance on providing adequate ventilation for safe indoor use, including carbon monoxide warnings and opening requirements.

Maintenance

Wiring Diagrams

Troubleshooting Guide

Exploded View

Parts List

Limited Warranty