Questions and Answers

  • J
    Jason RogersAug 12, 2025
    What to do if Status Light (3) is flashing and Pixie RP10 generator is beeping?
    • M
      Mr. David Lopez Jr.Aug 12, 2025
      If the Status Light (3) is flashing and the Pixie Inverter generator is beeping, it could be due to a few reasons. First, the pump might not be running because of a blocked filtration system or an air lock. A large air bubble in the electrode housing can trigger this alarm. Try cleaning out the skimmer box, checking for and clearing any blockages, and re-priming the pump. Second, the electrode lead might not be properly plugged in; ensure it's securely connected to the electrode.
  • C
    charlesmarksAug 16, 2025
    Why is my Pixie RP10 chlorine generator not generating enough chlorine?
    • N
      Nathan PerezAug 16, 2025
      If the Pixie Inverter chlorine generator isn't producing enough chlorine, there are several potential causes. First, the chlorine production might be set too low; adjust the control knob clockwise to increase it. Second, the generator might not be operating for a sufficient amount of time; increase its running time. Third, the electrode might be calcified, requiring cleaning. Lastly, the water chemistry could be incorrect; make sure to correct it.
  • K
    Kathleen WagnerAug 20, 2025
    Why is the high salinity light on my Pixie RP10 Inverter flashing?
    • B
      Barbara RamirezAug 20, 2025
      If the high salinity light is on or flashing on your Pixie Inverter, it means one of two things: either the pool salinity is too high, or the chlorine generator is faulty. To resolve this, have the salinity level tested by a pool professional and reduce it to 5,500 ppm if necessary. If the salinity is correct, contact your dealer or AIS Water, as the generator may be faulty.
  • M
    Mrs. Melanie DanielAug 25, 2025
    What does it mean when the low salinity light is flashing on my Pixie RP10?
    • D
      Dakota YoungAug 25, 2025
      If the low salinity light is on or flashing on your Pixie Inverter, it indicates that either the water salinity is too low, the electrode is calcified, or the electrode is faulty. To address this, first have the salinity level tested by a pool professional and increase it to 4000 ppm if necessary. If the salinity is correct, clean the electrode. If the issue persists, have the electrode tested and replaced if necessary.
  • T
    Timothy RayAug 27, 2025
    How to fix no lights on chlorine generator and pump not running on Pixie RP10?
    • M
      mark98Aug 27, 2025
      If there are no lights on the chlorine generator and the pump isn't running on your Pixie Inverter, it could be due to a lack of mains power. Unplug the chlorine generator from the power and test the power outlet with another working appliance. Alternatively, the time clock might be in a designated off period, or the switch might be in the OFF position; switch to BYPASS to circumvent TIMER or OFF functions.
  • M
    Michelle GarciaAug 31, 2025
    Why is Status Light (3) on but no other lights on Pixie RP10 Inverter?
    • B
      bergerkimberlyAug 31, 2025
      If the Status Light (3) is on and the pump is running, but no other lights are on for your Pixie Inverter, the chlorine generator production is likely turned off. To resolve this, adjust the control knob clockwise to increase production.
  • C
    Christopher KingSep 3, 2025
    What to do if there is white powdery material on pool bottom with Pixie Inverter?
    • R
      Raymond RiveraSep 4, 2025
      If you notice a white powdery material on the pool bottom when using your Pixie Inverter, it's likely due to excessive water hardness. To resolve this, test the water chemistry and adjust it accordingly.
  • E
    Erica BergSep 8, 2025
    Why is the circuit breaker tripping with my Pixie RP10 Inverter?
    • J
      James BradySep 8, 2025
      If the circuit breaker is tripping with your Pixie Inverter, it could be due to a few reasons. First, there might be a mains power surge. Set the machine to off and push the circuit breaker. Second, there could be a fault with shorted electrodes. Visually inspect the electrode and check for foreign or conductive surfaces. If found, remove and clean the cell. Also, check that the electrode plates are not contacting/touching each other; if they are, replace the cell. If neither of these resolves the issue, there may be a fault with the power supply, in which case you should contact your dealer or AIS Water.

Summary

Chlorine Generator Functions

Chlorine Controller

Adjusts chlorine output by turning clockwise to increase and anti-clockwise to reduce.

Chlorine Generator Installation

Fitting the Chlorinator Cell Housing

Plumbing the cell housing into the pool return line after filter and valves.

Gas Trap Installation

Ensuring a gas trap is formed to prevent damage from gas build-up.

Installing the Power Supply

Mounting the power supply securely, protected from elements, with airflow.

Raising Pool Salinity

General Chlorinator Operation

Chlorinator Running Times

Power Supply Control Functions

Time Clock Operations

Maintenance

Electrode Cleaning

Procedure for cleaning electrodes using a hydrochloric acid solution.

Troubleshooting Guide

No Lights and Pump Not Running

Troubleshooting steps for no power to the unit or pump.

Insufficient Chlorine Production

Reasons and solutions for low chlorine output from the generator.

Status Light 3 Flashing with Beeping