THE TImING mENU
The parameters on the Timing menu all relate to the

THE DWELL pARAmETER
(DWELL)
The Dwell parameter sets the amount of time that the
solenoid is energized and therefore the amount of gas
that is released with each shot of the
Etek STAR Frame. Setting this parameter
too low will result in low velocity shots
and/or excessive shot to shot velocity

high will simply waste gas and make the
Etek STAR Frame louder.
The DWELL can be set between 0.0 and
25.0 milliseconds. The factory default
setting can normally be reduced after
a few thousand shots as the marker
‘beds-in’.
THE FIRST SHOT DROp-OFF
COmpENSATION pARAmETER
(FSDO)


caused by the stiction between dynamic o-rings and
the surfaces that they are in contact with. In order to
compensate for FSDO this parameter can be set to add
extra time to the DWELL
parameter can be set between
0.0 and 3.0 milliseconds.