CHARGE STATUS INDICATOR
TROUBLESHOOTING GUIDE
The code definitions provided are for informational purposes only. Please see
your dealer for diagnosis and repair.
# OF BLINKS CODE DEFINITION SOLUTION
1 Battery high voltage Check battery size and
condition; reset charger
(interrupt AC power for 15
seconds)
2 Battery low voltage
3 Charge time-out, battery
pack not reaching required
voltage, charger output
reduced due to high
temperatures
Check connections; operate
charger at lower ambient
temperature
4 Battery could not be trickle-
charged to minimum voltage
Check battery for shorted or
damaged cells
5
Charger shut down due to
overheating
Ensure sufficient cooling air
flow (open the hood) and
reset the charger (interrupt
AC power for 15 seconds)
6 Charger internal fault Reset charger (interrupt AC
power for 15 seconds);
return to qualified service
provider if fault persists