FINAL
DRIVE/JET
PUMP/BILGE
SYSTEM
Pump
To
Hull
Alignment
3.
Grease
the
large
pump
sealing
O-ring
and
apply
Marine
Grade
Silicone
Sealant
(PN
8560054)
to
the
bilge
siphon
tube(s),
cooling
water
supply
tube,
and
studs
(to
seal
stud
in
hull).
Install
pump.
4.
Hold
pump
inward
tightly
against
hull
while
an
assistant
tightens
stud
mounting
nuts
inside
hull.
Torque
evenly
in
three
steps
to
28
ft.
lbs.
(38.7
Nm).
Apply
Sealant
Tighten
28
ft.
lbs.
(38.7
Nm)
5.
Torque
pump
mounting
nuts
(outside
of
hull)
evenly
in
three
steps
to
28
ft.
lbs.
(38.7
Nm)
using
a
criss
cross
pattern.
6.
Check
to
be
sure
pump
housing
is
tight
against
hull.
To
inspect
pump-to-hull
fit,
measure
the
gap
between
the
hull
and
pump
housing
with
a
feeler
gauge.
If
a
gap
is
present
it
should
not
exceed
.010"
(.25mm).
3/00
5.26
Polaris
Sales
Inc.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaris Virage TX 2000 and is the answer not in the manual?

Polaris Virage TX 2000 Specifications

General IconGeneral
BrandPolaris
ModelVirage TX 2000
CategoryBoat
LanguageEnglish

Related product manuals