4
1.4 Printer installation requirements
• Site preparation
It is the responsibility of the customer to comply with all installation requirements and to
perform them during machine operation. If this is not done, the machine may not operate
properly.
• Work área
The working area refers to the area close to the POLAROID SECOND series machine
(hereinafter referred to as the equipment). It must be emphasized that the user should
ensure the safety of the operators in this area. The working area is 6m long, 4m wide and
3m high.
• Environmental requirements
The equipment shall be kept away from radio frequency sources. The floor shall be easy to
clean without generating dust and static electricity. In order to help operators and
customers judge the accuracy of color, neutral gray decoration and pure white light
(fluorescent lamp) should be used as far as possible. The equipment shall be installed in a
clean, dust-free environment where the temperature and relative humidity are controlled
within the following range: altitude: below 1000 meters above sea level; operating
temperature: 18-28 ℃; relative humidity: 40% - 60%.
• Load bearing requirements
POLAROID SECOND printer 200KG (140KG net weight without package) color fixing
machine 300KG (260KG net weight without package)
The equipment shall be installed at the place of relative plane and the anchor shall be
screwed down for support.
• Space reservation requirements
The front of the equipment refers to the input side of the machine. It is required to reserve
1.0m in front of the equipment. Keep 1.0m on the back and 1.0m on the left and right sides
respectively. In addition, the space reserved area also includes a height of 3 meters above
the ground. In addition, space should be left in front of and behind the machine for loading
and unloading pictures and consumables.
• Safety requirements
• Fire prevention
In order to prevent the danger caused by the accumulation of volatile gas, sufficient
ventilation must be provided to ensure that the air vent of the work area is low enough to
replace the air for 6 to 8 times every hour, so that the volatile gas cannot accumulate near
the floor.
The electrical equipment installed near the working area must comply with GB/T standards
and the provisions of the national electrical regulations on Class I and Class II sites, and shall
be installed by professional electrical contractors with corresponding qualifications. The
regulations on hazardous waste treatment shall comply with the special storage and
treatment requirements of relevant departments.