EasyManua.ls Logo

PondBuilder Clear water 1800 - User Manual

PondBuilder Clear water 1800
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Congratulations!
You have purchased a quality pump from PondBuilder, manufacturers of quality pond products. If you
experience trouble with your pump please reference the Troubleshooting section of this manual. If you
are unable to remedy the problem please contact your local PondBuilder dealer for further assistance.
IMPORTANT
PLEASE READ BEFORE USING YOUR PUMP
To insure proper operation of your pump and receive maximum life of this product, it is important that you
read the owners manual completely.
PondBuilder™ PUMP INFORMATION
PondBuilder™ products are created by experienced pond professionals. ese multi-purpose submersible
pumps are designed for use in water garden and Koi pond ltration systems, and to create waterfalls, streams
and water features. ey can also be used for other drainage applications, such as draining swimming pools,
and clearing water from a ooded basement.
Clear Water models are suitable for pumping clear ltered water, such as when using a PondBuilder™ Pond
Skimmer. Solids Handling pumps can be used for dirty water containing solid particles up to 1.18 inches
(30mm) in size. e temperature of the water being pumped must never exceed 95 degrees Fahrenheit. Do
not pump salty water, sewage, inammable, corrosive or explosive liquids (e.g. petrol, fuel, diluents),
greases, oils, or foodstus.
For Your Safety
e power cord must never be used to carry or move the pump.
Always use the pump’s handle.
e pump should be unplugged before taking any action on the pump including placing it
into or removing it from the water.
Never remove the plug from the power socket by pulling on the power cord.
If the power supply cord has been damaged, it must be replaced by the manufacturer or his
authorized customer support service in order to avoid all risks.
Installing the pump
• esepumpscanbeinstalledinapondskimmerordirectlyintoapondineitheraverticalor
horizontal position. * e Solids Handling 5040 & 6600 models are vertical installation only.
• Allmodelsincludeanelbow.UseTeontapewhenattachingttingstothepump.
• epumpmustremainsubmersedwhilerunning.Runningthepumpdrywillvoidthewarranty.
• Donotplacethepumpwhereitcanbecomecloggedwithdebrisorgravel.Donotsetthepumponthe
bottom of the pond to prevent the pump from draining the pond. Monitor the pump regularly to make
sure the intake remains unclogged.
• Plugthepumpintoagroundfaultinterrupter(GFCI)protectedoutletthatisinadryplace,protected
against any risk of ooding. Verify that the power supply voltage and frequency match the specications
on the pump nameplate.
Winter Operation
e pump may be run during cold weather, but it is absolutely essential to prevent the pump housing and
PVCpipefromfreezing.Intheeventicemayfreezearoundthepump,removethepumpfromthewater,
empty it and place it where it cannot freeze.
Overload Protection
epumphasathermaloverloadsafetydevice.Intheeventofanyoverheatingofthemotor,thisdevice
automatically switches o the pump. e cooling time is roughly 15 to 20 minutes, then the pump auto-
maticallycomesonagain.Iftheoverloadcutoutistripped,itisessentialtoidentifyanddealwiththecause
of the overheating.
6. TROUBLESHOOTING
Before taking any troubleshooting action, disconnect the pump from the power supply by
removing the plug from the socket.
Problem
e pump does not run.
e pump runs but
does not deliver water.
e pump stops
running automatically.
Possible causes
•Powercordunplugged.
•Impellerjammed.
•Waterlevelunderthe
suction minimum.
•Airbubbleinthepump,
produced during the plunge.
•Suctionlterclogged.
•Dischargetubecloggedor
obstructed.
e thermal overload protection system
stoppedthepump.Aforeignobjecthas
jammedthepump.epumpwasusedin
hot water. e pump ran dry.
Solutions
• Plugcordsecurelyintothe socket and check
if there is voltage on the line.
• Disconnectthepowercord,disassemblehydraulic
part and check if impeller is free to run.
• Checktoseeifthecircuitprotectorneeds
to be reset.
• Stopthepump,donotrunthepumpdry.
• Gettheairoutbyplungingagainthepump
while in a tilted position and shake it with the
discharge tube open.
• Disconnectthepowercord,cleanthe
pump bottom.
• Disconnectthepowercord:takeothetube
and clean it.
Disconnectthepowercord,correctthereason
for overheating; then wait until the pump is
cooled, plug the cord and resume operation.
Model CLEAR CLEAR CLEAR SOLIDS SOLIDS SOLIDS SOLIDS SOLIDS
WATER WATER WATER HANDLING HANDLING HANDLING HANDLING HANDLING
1800 2340 4200 1420 2160 3840 5040 6600
Voltage/frequency 115V/60Hz 115V/60Hz 115V/60Hz 115V/60Hz 115V/60Hz 115V/60Hz 115V/60Hz 115V/60Hz
Power Consumption 170-240Watts* 195-280Watts* 330-630Watts* 210-270Watts* 250-360Watts* 380-670Watts* 660Watts* 750Watts*
Max ow rate 1800 gph 2340 gph 4200 gph 1420 gph 2160 gph 3840 gph 5040 gph 6600 gph
Max Pumping Ht. 18 ft 22 ft 30 ft 12 ft 14 ft 26 ft 28.5 ft 35 ft
Amp Draw 2.2 2.5 6.2 2.4 3.3 6.2 6 6.1
PondBuilder Pump Specications
* Wattage will vary based on head pressure.
Question and Answer IconNeed help?

Do you have a question about the PondBuilder Clear water 1800 and is the answer not in the manual?

Summary

PondBuilder Pump Information

For Your Safety

Installing the Pump

Winter Operation

Overload Protection

Troubleshooting Guide

Pump Does Not Run

Addresses issues where the pump fails to start, checking power and impeller.

Pump Runs But No Water Delivery

Covers scenarios where the pump operates but water flow is absent due to air or blockages.

Pump Stops Automatically

Explains why the pump may stop unexpectedly, often due to overheating or foreign objects.

Warranty Information

18-Month Limited Warranty

Details the limited warranty terms for pumps against defects in material and workmanship.

For Your Records

Provides space for users to record important purchase and model details for warranty service.

Overview

The provided document is an owner's manual for PondBuilder™ pumps, offering comprehensive information about their function, installation, troubleshooting, and warranty.

Function Description:

PondBuilder™ pumps are multi-purpose submersible pumps designed for use in various water features and drainage applications. They are suitable for water garden and Koi pond filtration systems, creating waterfalls, streams, and other water features. Additionally, they can be used for drainage tasks such as emptying swimming pools or clearing flooded basements. The manual distinguishes between "Clear Water" models, which are designed for pumping clear filtered water (e.g., with a PondBuilder™ Pond Skimmer), and "Solids Handling" models, which can manage dirty water containing solid particles up to 1.18 inches (30mm) in size.

Important Technical Specifications:

The manual provides a table of specifications for various models, categorized as "Clear Water" and "Solids Handling." Common specifications across all models include:

  • Voltage/Frequency: 115V/60Hz.

Specific model specifications are as follows:

Clear Water Models:

  • 1800:
    • Power Consumption: 170-240 Watts
    • Max Flow Rate: 1800 gph
    • Max Pumping Ht.: 18 ft
    • Amp Draw: 2.2
  • 2340:
    • Power Consumption: 195-280 Watts* (Wattage will vary based on head pressure)
    • Max Flow Rate: 2340 gph
    • Max Pumping Ht.: 22 ft
    • Amp Draw: 2.5
  • 4200:
    • Power Consumption: 330-630 Watts
    • Max Flow Rate: 4200 gph
    • Max Pumping Ht.: 30 ft
    • Amp Draw: 6.2

Solids Handling Models:

  • 1420:
    • Power Consumption: 210-270 Watts
    • Max Flow Rate: 1420 gph
    • Max Pumping Ht.: 12 ft
    • Amp Draw: 2.4
  • 2160:
    • Power Consumption: 250-360 Watts* (Wattage will vary based on head pressure)
    • Max Flow Rate: 2160 gph
    • Max Pumping Ht.: 14 ft
    • Amp Draw: 3.3
  • 3840:
    • Power Consumption: 380-670 Watts
    • Max Flow Rate: 3840 gph
    • Max Pumping Ht.: 26 ft
    • Amp Draw: 6.2
  • 5040:
    • Power Consumption: 660 Watts* (Wattage will vary based on head pressure)
    • Max Flow Rate: 5040 gph
    • Max Pumping Ht.: 28.5 ft
    • Amp Draw: 6
  • 6600:
    • Power Consumption: 750 Watts* (Wattage will vary based on head pressure)
    • Max Flow Rate: 6600 gph
    • Max Pumping Ht.: 35 ft
    • Amp Draw: 6.1

General operating conditions:

  • Maximum water temperature: Never exceed 95 degrees Fahrenheit.
  • Not suitable for pumping salty water, sewage, inflammable, corrosive, or explosive liquids (e.g., petrol, fuel, diluents), greases, oils, or foodstuffs.

Usage Features:

  • Installation: Pumps can be installed in a pond skimmer or directly into a pond in either a vertical or horizontal position. Note that "Solids Handling 5040 & 6600" models are for vertical installation only. All models include an elbow, and Teflon tape should be used when attaching fittings.
  • Submersion: The pump must remain fully submersed while running; running it dry will void the warranty.
  • Placement: Avoid placing the pump where it can become clogged with debris or gravel. Do not set it directly on the bottom of the pond to prevent the pump from draining the pond completely. Regular monitoring is recommended to ensure the intake remains unclogged.
  • Electrical Connection: The pump must be plugged into a Ground Fault Circuit Interrupter (GFCI) protected outlet located in a dry place, protected against flooding. Verify that the power supply voltage and frequency match the pump's nameplate specifications.
  • Winter Operation: The pump can be run in cold weather, but it is crucial to prevent the pump housing and PVC pipe from freezing. If ice may form around the pump, it should be removed from the water, emptied, and stored in a non-freezing location.
  • Safety Precautions:
    • Always use the pump's handle for carrying or moving the pump; never use the power cord.
    • Always unplug the pump before taking any action, including placing it into or removing it from the water.
    • Never remove the plug by pulling on the power cord.
    • If the power supply cord is damaged, it must be replaced by the manufacturer or an authorized service agent to avoid risks.

Maintenance Features:

  • Overload Protection: The pump is equipped with a thermal overload safety device that automatically switches off the pump if it overheats. After cooling for approximately 15-20 minutes, the pump will automatically restart. If the overload cutout trips, it is essential to identify and address the cause of overheating before resuming operation.
  • Troubleshooting: The manual provides a detailed troubleshooting guide for common issues:
    • Pump does not run:
      • Possible causes: Unplugged power cord, jammed impeller, tripped circuit protector.
      • Solutions: Securely plug in the cord, check for voltage, disassemble the hydraulic part to check impeller, reset circuit protector.
    • Pump runs but does not deliver water:
      • Possible causes: Water level below suction minimum, air bubble in the pump, clogged suction filter, clogged or obstructed discharge tube.
      • Solutions: Stop the pump (do not run dry), re-plunge the pump in a tilted position and shake it with the discharge tube open, clean the pump bottom, remove and clean the discharge tube.
    • Pump stops running automatically:
      • Possible causes: Thermal overload protection system activated (due to foreign object jamming, use in hot water, or running dry).
      • Solutions: Disconnect power, correct the reason for overheating, wait for the pump to cool, then plug the cord and resume operation.

Warranty:

PondBuilder™ pumps come with an 18-month limited warranty against defective material and workmanship under normal use, starting from the date of purchase. This warranty is valid only if the pump is registered within 60 days of purchase. Replacement liability is limited to repairing or replacing defective parts at PondBuilder™'s discretion. Proof of purchase (invoice copy, sales ticket, etc.) is required for all claims. The warranty is void if the pump is not installed according to the instructions provided in the manual. All returned pumps will be inspected to determine the cause of failure. This limited warranty is exclusive and replaces all other warranties, expressed or implied, including merchantability or fitness for a particular purpose. It grants specific legal rights, which may vary by state.

PondBuilder Clear water 1800 Specifications

General IconGeneral
BrandPondBuilder
ModelClear water 1800
CategoryWater Pump
LanguageEnglish