| Suitable for ponds up to | 5000 liters |
|---|---|
| Suitable for ponds with fish stock | Yes |
| Suitable for ponds with koi | Yes |
| Weight | 4.5 kg |
| Filter volume | 10 L |
| Filter Material | Foam |
Unit use by children aged 8+ and persons with reduced capabilities requires supervision.
Ensure unit is fused, match electrical data, disconnect power before water contact, check cables/housings.
Electrical installations must meet national regulations and be performed by a qualified electrician.
Use splash-proof outdoor equipment; unit connections/plugs are not waterproof and must not be in water.
Maintain safety distance, handle unit safely, route cables, use original parts, and avoid technical changes.
For operation with clean water, mechanical and biological cleaning of garden ponds.
UVC lamp kills algae/bacteria; radiation harmful to eyes/skin, never use outside housing.
Do not use with fluids other than water, without water, for commercial purposes, or with chemicals.
Use hoses suitable for 1 bar, shorten adapters, secure with hose clips, and use sealing rings.
Install in flood-protected position at least 2m from water, avoid direct sun, keep accessible.
Switch pump first, then UVC; don't operate without water; unit auto-starts; biological effect takes weeks.
Isolate electrical units before reaching into water; isolate the device before working on it.
Isolate electrical units and device before cleaning or maintenance.
Disconnect hoses, attach dirt drain hose, pump handle to clear filters, reconnect hoses.
Disassemble filter, clean components under running water, reassemble, check seals.
UV radiation burns eyes/skin; never operate lamp outside or in defective casing.
Quartz glass and UVC lamp can break and cause cuts; handle with care.
Insert quartz glass, press O ring, tighten screws, push unit head into housing, turn clockwise to secure.
Prepare unit for storage below 8°C: drain, clean, dry filters, store frost-free and inaccessible.
Identify wear parts (lamp, glass, O-ring) and dispose of unit/lamps according to regulations.
Addresses performance issues, UVC lamp not lit, and no water outlet with cause and remedy.
2-year guarantee for material/manufacturing faults, excludes wear parts. Requires purchase receipt.