Touch Pad Quick Start Service Guide
A2463
Operating Instructions:
1. Enter 4 digit passcode (Default passcode 1234)
2. Press and hold “Cover or “Uncover” buttons until cover is in desired position
3. The keypad will automatically lock after the timeout specied (default 20 seconds)
Accessing settings menu:
1. Enter User 1 passcode (Menus are only accessible from User 1 or Service passcodes)
2. Press the “Press for Service” button
3.
Press Select (5) button to enter menu
4.
Use Up (2), Down (8) and Select (5) to navigate the menu options
5. Press the “Press for Service” button at any time to leave the menu option
The following Options are available in the settings menu:
SET PASSCODES: Enter user code number (1-4) and then enter passcode
(ie. Press 31111 to program user 3 to a passcode of 1111)
USER DEFAULTS:
KEY BEEP – Adjust beep tone
PADTIMEOUT – Adjust key lock timeout (10-60 seconds)
WIFI ENABLE – Not available on this model
SERVICE CALL* Feature not enabled
RF MODULE* Allows technician to turn on or off the RF module for remote Touch Pad applications
(Feature Controller with RF required for operation)
LINK TEST* - Display a real time signal strength for troubleshooting poor remote Touch Pad reception
RESET RF LINK* - Resets the RF radio to factory settings (re-sync with feature controller is
required for operation after reset)
WIFI CONNECT: Not available on this model
COVER FEATURES: (if feature controller is installed) – displays feature controller information
CALIBRATE POOL* - Allows Touch Pad to be calibrated to the specific pool installation sets
open and close time and average currents
CURRENT LIMITS* - Allows technician to ne tune average current and over current limits
EDIT PFSSCREEN* - Allows technician to reprogram the screen which is shown when the
“Press for Service” button is pressed
SYSTEM STATUS* - Displays system information such as cycle counts and rmware version
FACTORY SETUP* - Will reset the Touch Pad back to original factory settings
* Only available in service mode
© Latham Pool Products, Inc. 2019. All rights reserved.