PORT-A-COOL®
PORTABLE EVAPORATIVE COOLING UNIT
OWNERS MANUAL
U.S. Patent 6,223,548
U.S. Patent D 362,905
U.S. Patent 6,502,414
FOR ELECTRIC MODELS
PAC2K482S, PAC2K361S, PAC2K363S, PAC2K36HPVS, PAC2K243S,
PAC2K24HPVS, PAC2K163S, PAC2K163SFC, PAC2K163SHD
Includes Export Models
PAC2K481S-230/50, PAC2K481S-220/60, PAC2K362S-230/50, PAC2K361S-230/50,
PAC2K36HPVS-220/50, PAC2K36HPVS-220/60, PAC2K361S-220/60, PAC2K242S-230/50,
PAC2K241S-230/50, PAC2K24HPVS-220/50, PAC2K161S-230/50, PAC2K161S-220/60, PAC2K161SFC-220/60

Questions and Answers

  • D
    Don AdkinsSep 23, 2025
    Why isn't my Port A Cool Freezer pump working when it has power?
    • M
      Margaret DunlapSep 23, 2025
      If the pump of your Port A Cool Freezer will not run, and power is available and the pump is functional, the switch might not be making closure contact. Check the continuity and replace the switch.
  • A
    Angelica ShepherdAug 25, 2025
    How to fix a Port A Cool Freezer fan motor that won't run and makes no sound?
    • W
      whitneymccoyAug 25, 2025
      If the fan motor of your Port A Cool Freezer doesn't run and makes no sound, the issue might be with the power cord, extension cord, switches, or circuit breaker. Try reconnecting the power or extension cord and resetting the breaker.
  • A
    Ashley WilkinsAug 25, 2025
    Why does my Port A Cool Freezer motor overheat and shut off?
    • C
      Cristina RuizAug 26, 2025
      If your Port A Cool Freezer's motor is overheating, shutting off, and then restarting, it could be due to several reasons. One possibility is that the extension cord gauge is too small; replace it with a 12-gauge cord. Another reason might be obstructed inlet air or the unit being too close to a wall; ensure a minimum of 36 inches of inlet clearance. Finally, the motor itself could be faulty, requiring a replacement.
  • A
    Amanda JohnsonAug 27, 2025
    Why is my Port A Cool Freezer pump cycling on and off?
    • S
      Steven WhiteAug 27, 2025
      If the pump in your Port A Cool Freezer is cycling on and off periodically, it could be due to a few reasons. The extension cord gauge might be too small, so replace it with a minimum 12-gauge cord. Alternatively, the sump tank might be empty, so fill it with water. Lastly, the spray bar valve might be closed; open the valve.
  • R
    Richard MarshallAug 27, 2025
    How to troubleshoot a Port A Cool Freezer pump that won't turn on?
    • R
      romerojasonAug 27, 2025
      If the pump of your Port A Cool Freezer will not run when the switch is turned on, the issue might be with the power cord, extension cord, switches, circuit breaker, switch box, or connections. Try reconnecting the power or extension cord, resetting the breaker, or reconnecting in the switch box.
  • M
    Mitchell DavidsonSep 15, 2025
    Why is my Port A Cool Freezer drain valve leaking?
    • B
      Brianna LeonSep 15, 2025
      If water is leaking from the drain valve of your Port A Cool Freezer, it could be due to a worn washer; replace the washer. Alternatively, the stem might be worn; replace the drain valve.
  • J
    John WhiteSep 12, 2025
    Why is my Port A Cool Freezer pump motor running but the pump isn't turning?
    • M
      Madison JonesSep 12, 2025
      If the pump motor of your Port A Cool Freezer is running but the pump is not turning, the issue might be with the set screws on the coupling. Try tightening the set-screw or replacing the coupling.
  • S
    Stephanie CollinsSep 14, 2025
    Why is my Port A Cool Freezer fan blade not turning and making a squealing sound?
    • J
      Joshua MillerSep 14, 2025
      If the fan blade of your Port A Cool Freezer doesn't turn and the unit makes a squealing sound, it could be due to a loose or broken fan belt; tighten or replace the fan belt. Alternatively, the fan pulley might be spinning on the shaft; tighten the pulley set screw.
  • D
    Donald RobinsonSep 5, 2025
    Why does my Port A Cool Freezer pump hum but not pump water?
    • E
      Emily MartinezSep 5, 2025
      If the pump of your Port A Cool Freezer hums when the switch is turned on but does not pump water, it could be due to a clogged inlet filter; try cleaning the filter. Another possibility is a locked pump motor, in which case you should replace the pump. There could also be other items on the circuit; remove them.
  • K
    Kyle MathewsSep 3, 2025
    Why is my Port A Cool Freezer overflowing or spitting water?
    • J
      Julie CraneSep 3, 2025
      If your Port-A-Cool Freezer unit overflows from the sump tank or is spitting water through the fan, the float valve hose might be loose at the bulkhead fitting or at the float valve; tighten the connections and/or replace the hose washers. Alternatively, the water pressure might be too high, preventing the float valve from shutting off (50 psi max.); reduce the water pressure by checking the in-line reducer. It's also possible that the float valve isn't seating properly; check for particles in the valve and replace the float valve if needed. Finally, adjust the spray bar valve to reduce excess water flow.

Summary

Introduction to Port-A-Cool

Understanding Evaporative Cooling

Explains the fundamental process of evaporative cooling and its principles.

Introduction to Port-A-Cool

Humiditys Role in Evaporative Cooling

Discusses how relative humidity affects the efficiency of evaporative cooling systems.

Introduction to Port-A-Cool

Port-A-Cools Evaporative Technology

Details how the Port-A-Cool unit utilizes evaporative cooling technology.

Unit Setup and Preparation

Unpacking Your Port-A-Cool Unit

Provides instructions for safely removing the unit from its packaging.

Unit Setup and Preparation

Cooling Media Removal and Inspection

Guides on how to remove cooling pads for inspection and cleaning.

Water and Electrical Connections

Step-by-step guide for connecting the unit's water supply and electrical power.

Unit Setup and Preparation

Electrical Connection Guidelines

Important safety and connection instructions for the unit's electrical power.

Operating Your Port-A-Cool

Unit Specifications Overview

Lists key technical specifications for the Port-A-Cool unit.

Operating Your Port-A-Cool

Optimal Unit Placement

Recommends ideal locations for positioning the unit for maximum effectiveness.

Filling the Water Sump Tank

Instructions on how to properly fill the unit's water reservoir.

Pump Operation and Water Flow Adjustment

Details on starting the pump and regulating water flow to the cooling pads.

Operating Your Port-A-Cool

Starting the Fan System

Guide on how to safely start the unit's fan for operation.

Maintenance and Storage Procedures

Daily Unit Maintenance

Routine checks and actions for daily upkeep of the unit.

Weekly Unit Maintenance

Recommended maintenance tasks to be performed on a weekly basis.

Maintenance and Storage Procedures

Proper Unit Storage

Instructions for storing the unit when not in use to protect it.

Troubleshooting and Repair Guide

Common Troubleshooting Steps

Identifies common issues and provides solutions for the unit's operation.

Fan System Components and Issues

Belt Drive Fan System Troubleshooting

Specific troubleshooting for belt-driven fan models.

Fan System Components and Issues

Direct Drive Fan System Troubleshooting

Specific troubleshooting for direct-drive fan models.

Water System Components and Issues

Water System Components and Issues

Water Inlet System Troubleshooting

Addresses problems related to the unit's water inlet connections.

Plumbing Assembly Troubleshooting

Solutions for issues within the unit's water plumbing system.

Spray Bar Assembly Troubleshooting

Guides for resolving problems with the water spray bar.

Water System Components and Issues

Shaft Type Pump Troubleshooting (16 Models)

Specific troubleshooting for shaft-type pumps in 16-inch models.

Unit Repair Procedures

Fan Motor Replacement Guide

Step-by-step instructions for replacing the fan motor.

Unit Repair Procedures

Direct Drive Fan Motor Replacement

Specific guidance for replacing fan motors in direct drive configurations.

Unit Repair Procedures

Pump Replacement Guide

Detailed instructions for replacing the unit's pump.

Technical Support Information

Ordering Replacement Parts

RMA Procedures for Parts

Outlines the process for returning parts for warranty or repair.

Ordering Replacement Parts

Port-A-Cool Unit Limited Warranty

Details the terms and conditions of the unit's limited warranty.

Appendix A: Performance Data

Output Characteristics: 10-25% RH

Performance data tables for varying dry bulb temperatures at low relative humidity.

Appendix A: Performance Data

Output Characteristics: 30-45% RH

Performance data tables for varying dry bulb temperatures at moderate relative humidity.

Appendix A: Performance Data

Output Characteristics: 50-65% RH

Performance data tables for varying dry bulb temperatures at higher relative humidity.

Appendix A: Performance Data

Output Characteristics: 70-75% RH

Performance data tables for varying dry bulb temperatures at very high relative humidity.

Port A Cool PAC2K481S-220/60 Specifications

General IconGeneral
ModelPAC2K481S-220/60
Cooling Capacity48000 BTU
Power Supply220V/60Hz
Airflow6, 500 CFM
Weight245 lbs