19ENG N000732
PROBLEM CAUSE CORRECTION
Motorwillnotrun. Fuseblown,circuit
breaker tripped.
Checkfusebox
for blown fuse and
replace as necessary.
Resetcircuitbreaker.
Do not use a fuse or
circuit breaker with
higher rating than
that specified for your
particular branch circuit.
Checkforproper
fuse. You should use
a time delay fuse.
Checkforlow
voltage problem.
Checkthe
extension cord.
Disconnect the other
electrical appliances
from circuit or operate
the compressor on its
own branch circuit.
Extension cord is wrong
length or gauge.
Checkthe
extension cord.
Loose electrical
connections.
Checkwiringconnection
inside terminal box.
Faultymotor. Havecheckedby
aTrainedService
Technician.
Motoroverload
protection switch
has tripped
Referto"MotorOverload
Protection" under
Operation.Ifmotor
overload protection
trips frequently,
contact a Trained
ServiceTechnician

Table of Contents