© 1/14 Power Gear #3010001345 Rev. 0C
Installation and
Service Manual
Room Slideout System
with Programmable
Control
Introduction
SYSTEM DESCRIPTION
Your Power Gear Slideout System is a rack and pinion design operated by a 12
Volt DC electric motor.
MAJOR COMPONENTS
· Inner rail assemblies are designed to support the room weight.
· The 12 Volt DC gearmotor will operate the room using power from the on-board
unit battery.
· Slideout systems are equipped with a manual override that allows you to extend
/ retract the room in the event of a loss of power.
· A specially designed control that gives the user full control of room movement, in
or out. The control has programmable stops that stop the motor when the room
is fully extended or retracted and the ability to detect faults for ease in
troubleshooting.
Installation
Installation & Service Manual
Room Slideout System with
Control Box 1510000120 and
1510000121
1
1
2
2-3
4
4
5
5
CONTENTS
Introduction
Installation
Installation Problems
Program Mode
Operation Mode
Preventative Maintenance
Fault Diagnostics
Troubleshooting
Override Modes
Wiring Diagram
6-7
7

P/N 81-1291) for proper installation of rail assemblies.

installation of room locks.
Control and touchpad Installation. Refer to proper wiring diagram in back of manual

nents from the elements and being hit but is easily accessible for service.

in view of slideout room and have a minimum depth of 1” inside the wall.
Cut 2 7/8“ wide x 1 3/4” high rectangular opening in wall to mount the
touchpad.
3. Route and attach touchpad harness to where touchpad will be mounted.
 
4. If using room locks, route and attach room lock harness from control to
room lock.
5. Route and attach the motor and sensor harness from the control box to
the slideout room motors.
6. Route and attach the proper gauge wire from the control to the chassis
battery.
WARNING
S
!
Always keep away from the
slide-out room and rails when
the room is being operated. The
gear assembly may pinch or
catch on loose clothing causing
personal injury
Failure to follow these instruc-
tions could result in serious
injury or death

Questions and Answers

  • L
    Leslie RodriguezAug 18, 2025
    What to do if the Power Gear Motorhomes slideout motor is drawing excessive current?
    • D
      dmorganAug 18, 2025
      If the slideout motor is drawing excessive current, it may be due to excessive system/room drag, an obstruction, improper stop locations, or a damaged component. You should remove any obstructions, readjust the room, reset the stops, or replace any damaged components.
  • C
    Clifford HernandezAug 21, 2025
    What to do if my Power Gear Motorhomes show low battery voltage during room movement?
    • P
      Pamela ThompsonAug 21, 2025
      If you are experiencing low battery voltage (below 10.5V) when initiating room movement, it could be due to a bad wire connection from the battery to the control or a low battery. Repair the bad wire connection or replace the battery.
  • A
    ajacksonAug 23, 2025
    What to do if my Power Gear 1510000120 experience a battery voltage dropout below 8.0V?
    • M
      martindeniseAug 23, 2025
      If the voltage drops below 8.0V, it indicates a battery dropout. This could be caused by a bad battery, a bad wire connection, or a short in the system. You should repair any bad wire connections or shorts, or replace the battery.
  • P
    Preston OlsonAug 26, 2025
    What causes a short in a Power Gear 1510000120 slideout motor?
    • R
      rallenAug 26, 2025
      A short in the slideout motor can be caused by shorted wiring or the motor itself. Inspect the motor harness wires and the motor for shorts. Replace the shorted component.
  • J
    Jason LynchAug 27, 2025
    What causes excessive battery voltage in Power Gear Motorhomes?
    • J
      Jennifer TylerAug 27, 2025
      Excessive battery voltage (above 18.0V) during room movement is often due to a bad battery. Replace the battery.
  • M
    Matthew Johnson MDAug 30, 2025
    What to do if Power Gear Motorhomes show an open slideout motor?
    • K
      kimberly87Aug 30, 2025
      An open slideout motor can be caused by a bad connection, a faulty motor, or a blown fuse. Repair any bad wire connections, replace the motor, or replace the fuse.
  • W
    williamspaulSep 1, 2025
    What causes excessive current draw in a Power Gear Motorhomes room lock motor?
    • M
      Mrs. Christina GreenSep 1, 2025
      Excessive current draw in the room lock motor can be caused by excessive drag or obstruction, or a damaged component. Remove any obstructions or replace the damaged component.
  • N
    Nicholas TurnerSep 3, 2025
    What causes a short in a Power Gear 1510000120 room lock motor?
    • A
      Andrew SmithSep 3, 2025
      A short in the room lock motor is typically caused by shorted wiring or the motor itself. Inspect the motor harness wires and the motor for shorts, and then replace the shorted component.
  • T
    Thomas WeissSep 6, 2025
    What to do if Power Gear Motorhomes show an open room lock motor?
    • J
      Julia YatesSep 6, 2025
      An open in the room lock motor can be caused by a bad connection or a faulty motor. Repair the bad connection or replace the motor.
  • N
    ngutierrezSep 8, 2025
    What causes a room lock timeout in Power Gear 1510000120 Motorhomes?
    • W
      Wendy SuttonSep 8, 2025
      A room lock timeout can occur due to a bad wire connection, an obstruction, a broken component, or low voltage. Remove any obstructions, replace the battery, repair the bad wire connection, or fix the broken component in the room lock.

Summary

Introduction to Slideout System

System Description

Overview of the rack and pinion slideout system operated by a 12 Volt DC electric motor.

Major Components

Details the main parts of the slideout system, including inner rail assemblies and gearmotor.

Slideout System Installation

Control and Touchpad Installation

Instructions for mounting the control box and touchpad, and routing wiring.

Troubleshooting Installation Issues

Slideout System Program Mode

Program Mode Overview

Explains the procedure for setting IN and OUT stops and changing current stop settings.

Program Mode Setup

Setting the Retracted (IN) Stop Position

Details the steps to set the fully retracted position for the slideout room.

Setting the Extended (OUT) Stop Position

Details the steps to set the fully extended position for the slideout room.

Slideout System Operation Modes

Extending the Slideout Room

Step-by-step guide to extend the slideout room, including safety checks and lock operation.

Retracting the Slideout Room

Step-by-step guide to retract the slideout room, including safety checks and lock operation.

Slideout System Preventative Maintenance

Recommended Maintenance Procedures

Simple procedures to ensure long life of the slide-out system, including inspection and lubrication.

Slideout System Fault Diagnostics

Fault Code Identification and LED Indicators

Explains how to identify faults using LED flashes and lists fault codes, descriptions, causes, and solutions.

Troubleshooting Faults and Solutions

Provides a detailed table for diagnosing and resolving various system faults and their probable causes.

Slideout System Override Modes

Manual Emergency Retract Mode

Procedure to manually retract the room when there is no power loss or electrical problem.

Emergency Retract Module (ERM) Procedure

Details an alternate procedure using a specific kit to bypass the control for retraction.

Manual Crank Override Mode

Instructions for mechanically operating the room using override couplers if other methods fail.

Slideout System Wiring Diagrams

Touchpad Harness Wiring Details

Details the connections for the touchpad, including button functions and LED indicators.

Room Lock Harness Wiring Details

Illustrates the wiring connections for the room lock system.

Slideout Motor Harness Wiring Details

Shows the wiring diagram for connecting the slideout motors and sensors.