Copyright © 2016 VARO NV P a g e | 9 www.varo.com
13 PROBLEM-SOLVING
Cause
Solution
1. It is not plugged into the power
supply.
2. The wires are broken or
ripped.
3. Switch Malfunction
4. The capacitor is burned
through.
5. End-switch has not been reset
or a micro switch error
6. The thermal switch has
suffered a wire break.
1. Connect the item to the
power supply.
2. Check the wires and plug
it in again to the outlet.
3. Repair switch or change it
4. Change your capacitor
5. Check the end-switch and
replace the limit switch.
6. Wait until the item cools
down, or replace the thermal
switch.
1. The voltage offered is too
small.
2. The capacitor has become
damaged.
3. The brake is not completely
open.
1. Adjust the work,
depending on the power
supply
2. Change power supply.
3. Allow the machine to be
repaired from a qualified
repair service
The air between the brakes
is too large
The brake spring is ripped.
The brake disk is locked
The brake disk is at the start
already dirty.
Allow the machine to be
repaired from a qualified
repair service.
1. Badly oiled
2. After a long use, the cogwheel
and bearings are damaged.
3. Badly installed or dent
1. Oil/Grease machine
officially.
2. Change the cogwheel or
bearings.
3. Check installed parts or let
a qualified person check this
1. Earthed error or is not possible
2. The internal connectors are
touching the housing
1. Checked earthed wires
and properly connect them.
2. Check all internal
connections
1. The end-switch is defect
2. End-switch is blocked
1. Switch off or change
2. Check, repair, and change
End switch