When transporting:
•Do not overfill the tank.
•Do not operate the generating set while it is on vehicle. Take the generating set
off the vehicle and use it in a well-ventilated place. Avoid a place exposed to
direct sunlight when putting the generating set on a vehicle. If the generating set is
left in an enclosed vehicle for many hours, high temperature inside the vehicle
could cause fuel to vaporize resulting in a possible explosion.
•Do not drive on a rough road for an extende
d period with the gener
ating set on a
rough road, drain the fuel from the generating set beforehand.
27
Step1: Loosen 2 fixed bolts on the inverter. Step2: Loosen 2 fixed bolts on the control panel.
Step3: Pull apart the panel slowly. Step4: Loosen 3 bolts on the recoil starter.
1
3
4
2
How to replace the recoil starter in steps