F10R REFLECTIVE PHOTOCELL DETECTOR
INSTRUCTION MANUAL
COMFORT AND SECURITY
INSTALLATION
X
F10R Reective
photocell detector
PHOTOCELL DETECTOR FEATURES:
P04985 - Rev. 2
PRECAUTIONS
SPECIFICATIONS
- Max range: 08 meters (~26.25 feet)
- Operating voltage: 12Vdc - 24Vdc;
- Current drain: 80mA;
- NO and NC outputs;
- Immediate triggering;
- Pulsed output for PPA Control boards.
Round Reector
Connection terminal
( + ) ( - ): The device must be powered
by a 12Vdc - 24Vdc auxiliary power
supply;
P: Pulsed output for PPA Control
boards;
NA, C and NF: Relay dry contact
outputs. Used for circuit keying
when the photocell is used in
normal mode, either open or closed.
Step 1: Attach the photocell detector the same side the control
board is installed, since it will both receive commands from it and
power it up. The receiver is attached the opposite side, with the
transmitter and receiver facing each other. When attaching the
round reector, mind the (Installation) Position Indicator, it must
face up. ( ). The photocell detector must be attached so
that the opening for the wiring faces down, in order to
avoid accidental water entering.
A installation diagram can be seen on the previous page.
- Make sure the
wiring is facing down;
- Install the photocell
away from obstacles
which could block the
beam.
LED Indicator
Transmitter
Receiver
Wiring
Position indicator
(for installation)
The height indicated by an “X” refers to the height of the
possible objects which will be detected by the device, such as
vehicles, people and pets. For example, for a 50cm (~1.65f) high
vehicle, the photocell detector must be installed over this
height, otherwise it will not detect the vehicle. One must
observe the minimum height (30 cm - ~0.99f), in order to both
ensure a proper operation and avoid false alarms.
Note: There is no maximum height for installing the photocell
detector.
Question and Answer IconNeed help?

Do you have a question about the PPA F10R and is the answer not in the manual?

PPA F10R Specifications

General IconGeneral
BrandPPA
ModelF10R
CategorySecurity Sensors
LanguageEnglish

Summary

Photocell Detector Features

F10R Reflective Photocell Detector

Description and components of the F10R Reflective photocell detector, including transmitter and receiver.

Round Reflector

Details about the round reflector used with the photocell detector, including its position indicator.

Precautions

Installation Precautions

Important installation precautions for the photocell detector, focusing on wiring orientation and obstacle avoidance.

Connection Terminal

Terminal Connections and Wiring

Explanation of the photocell detector's connection terminal, including power, output types, and wiring details.

Installation

Step 1: Attaching the Photocell

First step of installation: attaching the photocell detector and reflector, ensuring proper orientation and spacing.

Specifications

Technical Specifications

Key technical details of the photocell detector, including range, voltage, current, and output types.

Object Detection Height

Height Adjustment

Guidance on setting the detection height for various objects and the minimum height requirement.

LED Functions

LED Indicator Status

Explanation of different LED indicator states and their meaning for detector alignment and operation.

Operation Mode Setup

Setting Operation Modes

Procedures for setting the photocell detector operation mode, including 'Coded PPA', 'NO', and 'NC' modes.

ATIV/PASS Jumper

Information on the ATIV/PASS jumper and its function in changing the relay operation mode.

Power Connection

Connecting Auxiliary Power

Instructions for connecting the auxiliary power supply to the photocell detector, emphasizing polarity.