9 Basic troubleshooting
40
9. Basic troubleshooting
Problem / symptom
Cause / remedy
Check the following if the engine does
not start:
Engine switch is in the "Start" position.
Fuel cock is open.
Fuel is replenished.
Choke lever is in the correct position. The choke should
be closed when starting a cold engine.
No electric equipment is connected to the generator.
Spark plug is in good condition.
Spark plug cap is firmly seated.
Engine oil level is sufficient.
Check the following if the engine
starts, but the generator does not
deliver any power to plug receptacles:
Fuse switch is closed.
Wiring from the generator to the plug receptacles is
secured.
Check the following if the engine
starts, but runs irregularly:
Air cleaner condition.
Condition of the spark plug and spark plug cap.
How new the fuel is.