FAULT LIKELY CAUSE SOLUTION
Low open circuit voltage Ø Blown line fuses.
Ø Blown primary fuse
> Measure the 3 line phases
> Change fuses
The ventilator does not
work
Ø Faulty motor
Ø Cut or loose ventilator power cables
Ø 2 or 4 A fuses blown
> measure the voltage of the motor
cables. If it is 230 V the motor is
faulty.
> Change fuses.
Poor welding current Ø Loss in the cables
Ø Faulty wire feed
> Tighten connections
> Lessen the wire feed roller pressure.
> Clean the torch tip
> Clean the rollers or change them if
faulty.
Gas holes in weld Ø Insufficient shielding gas flow
Ø Welded part is rusty or dirty.
Ø Moisture present in gas
> Reduce the feed speed.
> Increase the arc voltage.
Lack of penetration Ø Irregular position of torch
Ø Very low voltage
Ø Too large a margin
Ø Irregular wire feed
Ø Excessive projection
> Increase the arc voltage
Spatter Ø very high voltage
Ø dirt or spatter on tip
Ø insufficient inductance
Ø too much angle on torch
> Reduce the arc voltage
> Clean or change the tip
> Change the earth connection to
max. ind.