955205_01 11/11 5
System Overview
Flow Meter
727305 & 727306
The Flow Meter measures the rate at which the
liquid is owing through the system and is used to
indicate the applicaon rate of the product. The
Flow Meter should be installed vercally inline
between the liquid pump and distribuon. This
placement ensures that the rate indicated to the
user is for that of the enre system. The sensor on
the Flow Meter will be connected to the Flow
Meter Harness. There are two Flow Meters
available. The Standard Flow (727306) is for rates
of 2 – 40 gpm, and the Low Flow (727305) for rates
of .5 – 12 gpm. The Low Flow meter is
disnguished with a red zip e aached.
Flow Meter Harness
727303
The Flow Meter Harness connects the Flow
Meters sensor (3-pin Metripack) to the RowFlow
system through the Row Unit Module’s (RUM)
auxiliary port (6-pin Deutsch).